The WEG 14417256 (WEG material number 14417256) is a G Plus-line brushless synchronous alternator for industrial generator sets. WEG lists it as “GTA251AIHE IP23 B15T SAE 2/SAE 11,5”. Key specifications: model GTA251AIHE, frame (IEC) 250.0, number of poles 4, rated speed - 60 Hz 1800 rpm.

Drawing on WEG's deep design and manufacturing experience, the G Plus Line of Alternators is a modern, world-class range of brushless synchronous alternators for the global market. It serves a broad set of continuous, prime and standby applications across industrial, agriculture, marine, commercial, mining, healthcare and other sectors.

WEG 14417256 Technical Specifications

Manufacturer WEG
Part number 14417256
WEG material number 14417256
WEG designation GTA251AIHE IP23 B15T SAE 2/SAE 11,5
Product type Alternator
Series G Plus
Alternators for Generator Sets
Degree of Protection IP23
Cooling IC01
Excitation System Brushless with Auxiliary Coil
Mounting B15T
Coupling disc SAE 11,5
Flange Type SAE 2
Type of Pole Salient
Insulation Class 180°C (H)
Frame (IEC) 250.0
Painting Plan 207A
Operation mode NETWORK PARALLEL OPERATION
Finish Color MATTE BLACK
Voltage Regulator Inside of main terminal box
Standard IEC/NEMA
Model GTA251AIHE
THD (L-L, no load) ≤ 3%
Altitude up to 1000 m.a.s.l
Stator winding pitch 2/3
Number of Leads 12
Power Factor 0.8 to 1.0
Number of poles 4
Rated speed - 50 Hz 1500 rpm
Rated speed - 60 Hz 1800 rpm
Overspeed 2250 rpm
Approx. weight 460 kg
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Voltages (V)
Y (series star) connection 380 V
YY (parallel star) connection 190 V
Δ (series delta) connection 220 V
ΔΔ (parallel delta) connection 110 V
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Output power (kVA)
Continuous 80/40 128.0
Continuous 105/40 147.0
Continuous 125/40 160.0
Standby 150/40 165.0
Standby 163/27 170.0
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 366.4%
X'd Direct axis transient reactance 21.6%
X''d Direct axis subtransient reactance 15.0%
Xq Quadrature axis sync. reactance 141.3%
X''q Quadrature axis subtrans. reactance 16.9%
X2 Negative sequence reactance 15.9%
X0 Zero sequence reactance 2.5%
T'd Direct axis trans. short circ. time constant 56.4ms
T''d Direct axis sub. short circ. time constant 1.6ms
T'do Transient open circuit time constant 988ms
T''do Subtrans. constant ofopened circuit 2.2ms
Ta Short circuit time const. of armature 8ms
uc Full load excitation voltage 46.0V
ic Full load excitation current 3.8A
ic No load excitation current 0.6A
Icc Sustained short-circuit current 729A
Kcc Short-circuit ratio 0.29
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Voltages (V)
Y (series star) connection 400 V
YY (parallel star) connection 200 V
Δ (series delta) connection 230 V
ΔΔ (parallel delta) connection 115 V
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Output power (kVA)
Continuous 80/40 143.0
Continuous 105/40 164.0
Continuous 125/40 180.0
Standby 150/40 196.0
Standby 163/27 206.0
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 372.6%
X'd Direct axis transient reactance 21.9%
X''d Direct axis subtransient reactance 15.2%
Xq Quadrature axis sync. reactance 143.7%
X''q Quadrature axis subtrans. reactance 17.1%
X2 Negative sequence reactance 16.1%
X0 Zero sequence reactance 2.5%
T'd Direct axis trans. short circ. time constant 56.4ms
T''d Direct axis sub. short circ. time constant 1.6ms
T'do Transient open circuit time constant 990ms
T''do Subtrans. constant ofopened circuit 2.2ms
Ta Short circuit time const. of armature 8ms
uc Full load excitation voltage 50.3V
ic Full load excitation current 4.1A
ic No load excitation current 0.8A
Icc Sustained short-circuit current 779A
Kcc Short-circuit ratio 0.3
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 3 (1~ - 50Hz - 190-200 V) – Voltages (V)
Single phase low zig-zag or single phase delta 190-200 V
Model 3 (1~ - 50Hz - 190-200 V) – Output power (kVA)
Continuous 80/40 73.9
Continuous 105/40 84.7
Continuous 125/40 92.4
Standby 150/40 101.2
Standby 163/27 105.5
Model 3 (1~ - 50Hz - 190-200 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 488.6%
X'd Direct axis transient reactance 28.8%
X''d Direct axis subtransient reactance 20.0%
Xq Quadrature axis sync. reactance 188.5%
X''q Quadrature axis subtrans. reactance 22.5%
X2 Negative sequence reactance 21.2%
X0 Zero sequence reactance 3.3%
T'd Direct axis trans. short circ. time constant 75.2ms
T''d Direct axis sub. short circ. time constant 2.1ms
T'do Transient open circuit time constant 1318ms
T''do Subtrans. constant ofopened circuit 2.9ms
Ta Short circuit time const. of armature 11ms
uc Full load excitation voltage 46.0V
ic Full load excitation current 3.8A
ic No load excitation current 0.8A
Icc Sustained short-circuit current 693A
Kcc Short-circuit ratio 0.38
Model 3 (1~ - 50Hz - 190-200 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 3 (1~ - 50Hz - 190-200 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Voltages (V)
Y (series star) connection 380 V
YY (parallel star) connection 190 V
Δ (series delta) connection 220 V
ΔΔ (parallel delta) connection 110 V
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Output power (kVA)
Continuous 80/40 154.0
Continuous 105/40 176.0
Continuous 125/40 192.0
Standby 150/40 205.0
Standby 163/27 214.0
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 524.9%
X'd Direct axis transient reactance 31.0%
X''d Direct axis subtransient reactance 21.6%
Xq Quadrature axis sync. reactance 202.4%
X''q Quadrature axis subtrans. reactance 24.3%
X2 Negative sequence reactance 22.9%
X0 Zero sequence reactance 3.6%
T'd Direct axis trans. short circ. time constant 56.4ms
T''d Direct axis sub. short circ. time constant 1.6ms
T'do Transient open circuit time constant 983ms
T''do Subtrans. constant ofopened circuit 2.2ms
Ta Short circuit time const. of armature 8ms
uc Full load excitation voltage 46.5V
ic Full load excitation current 3.8A
ic No load excitation current 0.6A
Icc Sustained short-circuit current 875A
Kcc Short-circuit ratio 0.18
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Voltages (V)
Y (series star) connection 416 V
YY (parallel star) connection 208 V
Δ (series delta) connection 240 V
ΔΔ (parallel delta) connection 120 V
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Output power (kVA)
Continuous 80/40 164.0
Continuous 105/40 188.0
Continuous 125/40 205.0
Standby 150/40 220.0
Standby 163/27 229.0
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 469.2%
X'd Direct axis transient reactance 27.6%
X''d Direct axis subtransient reactance 19.2%
Xq Quadrature axis sync. reactance 200.4%
X''q Quadrature axis subtrans. reactance 34.6%
X2 Negative sequence reactance 26.9%
X0 Zero sequence reactance 3.2%
T'd Direct axis trans. short circ. time constant 86.9ms
T''d Direct axis sub. short circ. time constant 2.3ms
T'do Transient open circuit time constant 1732ms
T''do Subtrans. constant ofopened circuit 3.1ms
Ta Short circuit time const. of armature 14ms
uc Full load excitation voltage 47.3V
ic Full load excitation current 3.9A
ic No load excitation current 0.8A
Icc Sustained short-circuit current 807A
Kcc Short-circuit ratio 0.21
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Voltages (V)
Y (series star) connection 440 V
YY (parallel star) connection 220 V
Δ (series delta) connection 254 V
ΔΔ (parallel delta) connection 127 V
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Output power (kVA)
Continuous 80/40 171.0
Continuous 105/40 196.0
Continuous 125/40 214.0
Standby 150/40 230.0
Standby 163/27 240.0
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 438.2%
X'd Direct axis transient reactance 25.8%
X''d Direct axis subtransient reactance 18.0%
Xq Quadrature axis sync. reactance 169.0%
X''q Quadrature axis subtrans. reactance 20.2%
X2 Negative sequence reactance 19.0%
X0 Zero sequence reactance 3.0%
T'd Direct axis trans. short circ. time constant 56.4ms
T''d Direct axis sub. short circ. time constant 1.6ms
T'do Transient open circuit time constant 987ms
T''do Subtrans. constant ofopened circuit 2.2ms
Ta Short circuit time const. of armature 8ms
uc Full load excitation voltage 48.2V
ic Full load excitation current 4.0A
ic No load excitation current 0.9A
Icc Sustained short-circuit current 842A
Kcc Short-circuit ratio 0.23
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Voltages (V)
Y (series star) connection 480 V
YY (parallel star) connection 240 V
Δ (series delta) connection 277 V
ΔΔ (parallel delta) connection 138 V
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Output power (kVA)
Continuous 80/40 180.0
Continuous 105/40 206.0
Continuous 125/40 225.0
Standby 150/40 243.0
Standby 163/27 252.0
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 388.1%
X'd Direct axis transient reactance 22.8%
X''d Direct axis subtransient reactance 15.9%
Xq Quadrature axis sync. reactance 149.7%
X''q Quadrature axis subtrans. reactance 17.8%
X2 Negative sequence reactance 16.8%
X0 Zero sequence reactance 2.6%
T'd Direct axis trans. short circ. time constant 56.4ms
T''d Direct axis sub. short circ. time constant 1.6ms
T'do Transient open circuit time constant 990ms
T''do Subtrans. constant ofopened circuit 2.2ms
Ta Short circuit time const. of armature 8ms
uc Full load excitation voltage 50.4V
ic Full load excitation current 4.1A
ic No load excitation current 1.3A
Icc Sustained short-circuit current 812A
Kcc Short-circuit ratio 0.29
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
Model 8 (1~ - 60Hz - 220-240 V) – Voltages (V)
Single phase low zig-zag or single phase delta 220-240 V
Model 8 (1~ - 60Hz - 220-240 V) – Output power (kVA)
Continuous 80/40 98.9
Continuous 105/40 113.3
Continuous 125/40 123.6
Standby 150/40 135.4
Standby 163/27 141.1
Model 8 (1~ - 60Hz - 220-240 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 584.3%
X'd Direct axis transient reactance 34.4%
X''d Direct axis subtransient reactance 24.0%
Xq Quadrature axis sync. reactance 225.4%
X''q Quadrature axis subtrans. reactance 26.9%
X2 Negative sequence reactance 25.4%
X0 Zero sequence reactance 4.0%
T'd Direct axis trans. short circ. time constant 75.2ms
T''d Direct axis sub. short circ. time constant 2.1ms
T'do Transient open circuit time constant 1316ms
T''do Subtrans. constant ofopened circuit 2.9ms
Ta Short circuit time const. of armature 11ms
uc Full load excitation voltage 48.2V
ic Full load excitation current 4.0A
ic No load excitation current 1.2A
Icc Sustained short-circuit current 772A
Kcc Short-circuit ratio 0.31
Model 8 (1~ - 60Hz - 220-240 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 8 (1~ - 60Hz - 220-240 V) – Other characteristics
Air flow 1.4 m³/s
Exciter stator winding resistance at 20ºC 12.17 ohm
Stator winding resistance at 20ºC 0.03877 ohm
Rotor winding resistance 1.0 ohm
Stator winding layers 2
Inertia WR² 1.42 kgm²
NDE Bearing 6214-2RS/ZZ
Coupling disc SAE 11,5
Flange Type SAE 2
Driving Machine Diesel engine
WEG catalog category Generation,Transmission and Distribution > Generators > Alternators for Generator Sets > Industrial > G Plus Line

Industrial Automation Co. offers the WEG 14417256 in new condition. Request a quote for current pricing, availability, and lead time.

Altre opzioni di pagamento

Opzioni di pagamento sicure

  • Risposta garantita entro 24 ore

    Invia una richiesta di preventivo e ricevi rapidamente dal nostro team un preventivo affidabile per mantenere operative le tue attività.

    Maggiori informazioni sulla spedizione
  • Garanzia di 24 mesi

    Il doppio dello standard di settore — protezione completa contro i difetti per 2 anni interi.

    Maggiori informazioni sulla garanzia
  • Disponibile in diverse condizioni

    Diverse opzioni di approvvigionamento per aiutarti a controllare i costi senza compromettere le prestazioni.

    Maggiori informazioni sulla garanzia
  • Catalogo completo

    Ampio inventario negli Stati Uniti e approvvigionamento rapido per Mitsubishi, Siemens, Schneider e molti altri marchi.

    Leggi di più
  • Scelto da oltre 65.000 clienti

    Produttori e strutture in tutto il Paese si affidano a noi per ricambi, riparazioni e assistenza.

    Leggi di più
  • Buying Options

    Tutti i prodotti sono coperti dalla garanzia di 2 anni di Industrial Automation Co.

    Condizione SKU Prezzo Garanzia Disponibilità Quantità Acquisto
    New 14417256-FS Garanzia estesa di 2 anni Chiama per verificare la disponibilità Chiama per verificare la disponibilità (877)-727-8757
  • Description

    The WEG 14417256 (WEG material number 14417256) is a G Plus-line brushless synchronous alternator for industrial generator sets. WEG lists it as “GTA251AIHE IP23 B15T SAE 2/SAE 11,5”. Key specifications: model GTA251AIHE, frame (IEC) 250.0, number of poles 4, rated speed - 60 Hz 1800 rpm.

    Drawing on WEG's deep design and manufacturing experience, the G Plus Line of Alternators is a modern, world-class range of brushless synchronous alternators for the global market. It serves a broad set of continuous, prime and standby applications across industrial, agriculture, marine, commercial, mining, healthcare and other sectors.

    WEG 14417256 Technical Specifications

    Manufacturer WEG
    Part number 14417256
    WEG material number 14417256
    WEG designation GTA251AIHE IP23 B15T SAE 2/SAE 11,5
    Product type Alternator
    Series G Plus
    Alternators for Generator Sets
    Degree of Protection IP23
    Cooling IC01
    Excitation System Brushless with Auxiliary Coil
    Mounting B15T
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Type of Pole Salient
    Insulation Class 180°C (H)
    Frame (IEC) 250.0
    Painting Plan 207A
    Operation mode NETWORK PARALLEL OPERATION
    Finish Color MATTE BLACK
    Voltage Regulator Inside of main terminal box
    Standard IEC/NEMA
    Model GTA251AIHE
    THD (L-L, no load) ≤ 3%
    Altitude up to 1000 m.a.s.l
    Stator winding pitch 2/3
    Number of Leads 12
    Power Factor 0.8 to 1.0
    Number of poles 4
    Rated speed - 50 Hz 1500 rpm
    Rated speed - 60 Hz 1800 rpm
    Overspeed 2250 rpm
    Approx. weight 460 kg
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Voltages (V)
    Y (series star) connection 380 V
    YY (parallel star) connection 190 V
    Δ (series delta) connection 220 V
    ΔΔ (parallel delta) connection 110 V
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Output power (kVA)
    Continuous 80/40 128.0
    Continuous 105/40 147.0
    Continuous 125/40 160.0
    Standby 150/40 165.0
    Standby 163/27 170.0
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 366.4%
    X'd Direct axis transient reactance 21.6%
    X''d Direct axis subtransient reactance 15.0%
    Xq Quadrature axis sync. reactance 141.3%
    X''q Quadrature axis subtrans. reactance 16.9%
    X2 Negative sequence reactance 15.9%
    X0 Zero sequence reactance 2.5%
    T'd Direct axis trans. short circ. time constant 56.4ms
    T''d Direct axis sub. short circ. time constant 1.6ms
    T'do Transient open circuit time constant 988ms
    T''do Subtrans. constant ofopened circuit 2.2ms
    Ta Short circuit time const. of armature 8ms
    uc Full load excitation voltage 46.0V
    ic Full load excitation current 3.8A
    ic No load excitation current 0.6A
    Icc Sustained short-circuit current 729A
    Kcc Short-circuit ratio 0.29
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Voltages (V)
    Y (series star) connection 400 V
    YY (parallel star) connection 200 V
    Δ (series delta) connection 230 V
    ΔΔ (parallel delta) connection 115 V
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Output power (kVA)
    Continuous 80/40 143.0
    Continuous 105/40 164.0
    Continuous 125/40 180.0
    Standby 150/40 196.0
    Standby 163/27 206.0
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 372.6%
    X'd Direct axis transient reactance 21.9%
    X''d Direct axis subtransient reactance 15.2%
    Xq Quadrature axis sync. reactance 143.7%
    X''q Quadrature axis subtrans. reactance 17.1%
    X2 Negative sequence reactance 16.1%
    X0 Zero sequence reactance 2.5%
    T'd Direct axis trans. short circ. time constant 56.4ms
    T''d Direct axis sub. short circ. time constant 1.6ms
    T'do Transient open circuit time constant 990ms
    T''do Subtrans. constant ofopened circuit 2.2ms
    Ta Short circuit time const. of armature 8ms
    uc Full load excitation voltage 50.3V
    ic Full load excitation current 4.1A
    ic No load excitation current 0.8A
    Icc Sustained short-circuit current 779A
    Kcc Short-circuit ratio 0.3
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 3 (1~ - 50Hz - 190-200 V) – Voltages (V)
    Single phase low zig-zag or single phase delta 190-200 V
    Model 3 (1~ - 50Hz - 190-200 V) – Output power (kVA)
    Continuous 80/40 73.9
    Continuous 105/40 84.7
    Continuous 125/40 92.4
    Standby 150/40 101.2
    Standby 163/27 105.5
    Model 3 (1~ - 50Hz - 190-200 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 488.6%
    X'd Direct axis transient reactance 28.8%
    X''d Direct axis subtransient reactance 20.0%
    Xq Quadrature axis sync. reactance 188.5%
    X''q Quadrature axis subtrans. reactance 22.5%
    X2 Negative sequence reactance 21.2%
    X0 Zero sequence reactance 3.3%
    T'd Direct axis trans. short circ. time constant 75.2ms
    T''d Direct axis sub. short circ. time constant 2.1ms
    T'do Transient open circuit time constant 1318ms
    T''do Subtrans. constant ofopened circuit 2.9ms
    Ta Short circuit time const. of armature 11ms
    uc Full load excitation voltage 46.0V
    ic Full load excitation current 3.8A
    ic No load excitation current 0.8A
    Icc Sustained short-circuit current 693A
    Kcc Short-circuit ratio 0.38
    Model 3 (1~ - 50Hz - 190-200 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 3 (1~ - 50Hz - 190-200 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Voltages (V)
    Y (series star) connection 380 V
    YY (parallel star) connection 190 V
    Δ (series delta) connection 220 V
    ΔΔ (parallel delta) connection 110 V
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Output power (kVA)
    Continuous 80/40 154.0
    Continuous 105/40 176.0
    Continuous 125/40 192.0
    Standby 150/40 205.0
    Standby 163/27 214.0
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 524.9%
    X'd Direct axis transient reactance 31.0%
    X''d Direct axis subtransient reactance 21.6%
    Xq Quadrature axis sync. reactance 202.4%
    X''q Quadrature axis subtrans. reactance 24.3%
    X2 Negative sequence reactance 22.9%
    X0 Zero sequence reactance 3.6%
    T'd Direct axis trans. short circ. time constant 56.4ms
    T''d Direct axis sub. short circ. time constant 1.6ms
    T'do Transient open circuit time constant 983ms
    T''do Subtrans. constant ofopened circuit 2.2ms
    Ta Short circuit time const. of armature 8ms
    uc Full load excitation voltage 46.5V
    ic Full load excitation current 3.8A
    ic No load excitation current 0.6A
    Icc Sustained short-circuit current 875A
    Kcc Short-circuit ratio 0.18
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Voltages (V)
    Y (series star) connection 416 V
    YY (parallel star) connection 208 V
    Δ (series delta) connection 240 V
    ΔΔ (parallel delta) connection 120 V
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Output power (kVA)
    Continuous 80/40 164.0
    Continuous 105/40 188.0
    Continuous 125/40 205.0
    Standby 150/40 220.0
    Standby 163/27 229.0
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 469.2%
    X'd Direct axis transient reactance 27.6%
    X''d Direct axis subtransient reactance 19.2%
    Xq Quadrature axis sync. reactance 200.4%
    X''q Quadrature axis subtrans. reactance 34.6%
    X2 Negative sequence reactance 26.9%
    X0 Zero sequence reactance 3.2%
    T'd Direct axis trans. short circ. time constant 86.9ms
    T''d Direct axis sub. short circ. time constant 2.3ms
    T'do Transient open circuit time constant 1732ms
    T''do Subtrans. constant ofopened circuit 3.1ms
    Ta Short circuit time const. of armature 14ms
    uc Full load excitation voltage 47.3V
    ic Full load excitation current 3.9A
    ic No load excitation current 0.8A
    Icc Sustained short-circuit current 807A
    Kcc Short-circuit ratio 0.21
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Voltages (V)
    Y (series star) connection 440 V
    YY (parallel star) connection 220 V
    Δ (series delta) connection 254 V
    ΔΔ (parallel delta) connection 127 V
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Output power (kVA)
    Continuous 80/40 171.0
    Continuous 105/40 196.0
    Continuous 125/40 214.0
    Standby 150/40 230.0
    Standby 163/27 240.0
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 438.2%
    X'd Direct axis transient reactance 25.8%
    X''d Direct axis subtransient reactance 18.0%
    Xq Quadrature axis sync. reactance 169.0%
    X''q Quadrature axis subtrans. reactance 20.2%
    X2 Negative sequence reactance 19.0%
    X0 Zero sequence reactance 3.0%
    T'd Direct axis trans. short circ. time constant 56.4ms
    T''d Direct axis sub. short circ. time constant 1.6ms
    T'do Transient open circuit time constant 987ms
    T''do Subtrans. constant ofopened circuit 2.2ms
    Ta Short circuit time const. of armature 8ms
    uc Full load excitation voltage 48.2V
    ic Full load excitation current 4.0A
    ic No load excitation current 0.9A
    Icc Sustained short-circuit current 842A
    Kcc Short-circuit ratio 0.23
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Voltages (V)
    Y (series star) connection 480 V
    YY (parallel star) connection 240 V
    Δ (series delta) connection 277 V
    ΔΔ (parallel delta) connection 138 V
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Output power (kVA)
    Continuous 80/40 180.0
    Continuous 105/40 206.0
    Continuous 125/40 225.0
    Standby 150/40 243.0
    Standby 163/27 252.0
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 388.1%
    X'd Direct axis transient reactance 22.8%
    X''d Direct axis subtransient reactance 15.9%
    Xq Quadrature axis sync. reactance 149.7%
    X''q Quadrature axis subtrans. reactance 17.8%
    X2 Negative sequence reactance 16.8%
    X0 Zero sequence reactance 2.6%
    T'd Direct axis trans. short circ. time constant 56.4ms
    T''d Direct axis sub. short circ. time constant 1.6ms
    T'do Transient open circuit time constant 990ms
    T''do Subtrans. constant ofopened circuit 2.2ms
    Ta Short circuit time const. of armature 8ms
    uc Full load excitation voltage 50.4V
    ic Full load excitation current 4.1A
    ic No load excitation current 1.3A
    Icc Sustained short-circuit current 812A
    Kcc Short-circuit ratio 0.29
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    Model 8 (1~ - 60Hz - 220-240 V) – Voltages (V)
    Single phase low zig-zag or single phase delta 220-240 V
    Model 8 (1~ - 60Hz - 220-240 V) – Output power (kVA)
    Continuous 80/40 98.9
    Continuous 105/40 113.3
    Continuous 125/40 123.6
    Standby 150/40 135.4
    Standby 163/27 141.1
    Model 8 (1~ - 60Hz - 220-240 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 584.3%
    X'd Direct axis transient reactance 34.4%
    X''d Direct axis subtransient reactance 24.0%
    Xq Quadrature axis sync. reactance 225.4%
    X''q Quadrature axis subtrans. reactance 26.9%
    X2 Negative sequence reactance 25.4%
    X0 Zero sequence reactance 4.0%
    T'd Direct axis trans. short circ. time constant 75.2ms
    T''d Direct axis sub. short circ. time constant 2.1ms
    T'do Transient open circuit time constant 1316ms
    T''do Subtrans. constant ofopened circuit 2.9ms
    Ta Short circuit time const. of armature 11ms
    uc Full load excitation voltage 48.2V
    ic Full load excitation current 4.0A
    ic No load excitation current 1.2A
    Icc Sustained short-circuit current 772A
    Kcc Short-circuit ratio 0.31
    Model 8 (1~ - 60Hz - 220-240 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 8 (1~ - 60Hz - 220-240 V) – Other characteristics
    Air flow 1.4 m³/s
    Exciter stator winding resistance at 20ºC 12.17 ohm
    Stator winding resistance at 20ºC 0.03877 ohm
    Rotor winding resistance 1.0 ohm
    Stator winding layers 2
    Inertia WR² 1.42 kgm²
    NDE Bearing 6214-2RS/ZZ
    Coupling disc SAE 11,5
    Flange Type SAE 2
    Driving Machine Diesel engine
    WEG catalog category Generation,Transmission and Distribution > Generators > Alternators for Generator Sets > Industrial > G Plus Line

    Industrial Automation Co. offers the WEG 14417256 in new condition. Request a quote for current pricing, availability, and lead time.

  • Documentation

    AI Product Assistant

    Ask questions about WEG 14417256

    Assistente IA

    Fai domande su WEG 14417256

    Domande suggerite

Quick search

Invia il tuo articolo per una valutazione gratuita e un preventivo di riparazione. Utilizza il nostro modulo RMA oppure invia una richiesta di riparazione a service@iac.us.com; ti contatteremo per valutare la situazione e fornirti le informazioni sulla spedizione.

Assistenza tecnica

Hai bisogno di aiuto con l’installazione, la configurazione o la risoluzione dei problemi? I nostri esperti tecnici sono a tua disposizione.

  • Assistenza telefonica

    (877) 727-8757

  • Assistenza via e-mail

    sales@iac.us.com

Ordina oggi i tuoi ricambi per l’automazione industriale

Industrial Automation Co. è un fornitore leader di componenti di ricambio e aftermarket per l’automazione industriale. Oltre a 14417256, offriamo centinaia di ricambi WEG attualmente disponibili nel nostro magazzino. La maggior parte dei nostri componenti per l’automazione viene spedita lo stesso giorno ed è coperta dalla nostra garanzia di due anni. Contattaci oggi stesso per ordinare i tuoi ricambi WEG.

Contattaci