Chiudi

Aggiunto correttamente

Il prodotto è stato aggiunto al preventivo.

Downtime prevention

How to Replace a FANUC CNC Battery Without Losing Parameters

A FANUC battery replacement takes about ten minutes. Done in the wrong order, it can cost you your parameters, part programs and axis positions. Here is how to back up, swap both batteries with power on, and recover if something goes wrong.

Get a quote November 11, 2026 | 8 min read

Most FANUC CNCs keep their parameters, part programs, tool offsets and macro variables in battery-backed memory. When that battery dies and the machine is powered down, the data can go with it. The fix is cheap and quick, as long as you replace the battery before it fails and you do it with the control powered on.

The two batteries on a FANUC CNC

A FANUC battery replacement usually means one of two batteries, and they protect different things. Know which one is asking for attention before you open the cabinet.

FANUC control battery vs APC battery

Control memory battery APC (encoder) battery
Protects Parameters, programs, offsets, macro variables Absolute axis positions
Location CNC control unit Servo amplifier or a separate battery case
Warning BAT on the screen APC alarms 306, 307, 308
If it fails Memory cleared at next power-off Alarm 300, reference return needed
Replace with Control power on Control power on

On Series 16i, 18i and 21i-B controls, the memory backup battery is a 3 V lithium cell that plugs into the control unit. On LCD-mounted units it sits on the back of the display assembly. Power Mate i controls use their own lithium backup battery in the same role. The absolute pulse coder (APC) battery keeps the encoders on each servo motor remembering where the axes are while the machine is off. On alpha i servo amplifiers it is a 6 V lithium pack that clips into the amplifier; older systems use a separate case of D-cell alkaline batteries.

In stock at IAC

GE Fanuc 16i/18i/21i-B replacement battery

Lithium memory backup battery for Series 16i, 18i and 21i-B controls. Ships today.

Buy now

Signs the battery is due

  • BAT on the screen. When the control memory battery runs low, the status line shows a blinking BAT warning. The machine still runs, but the clock has started. Replace it before the next planned power-down.
  • APC alarm 307 or 308. These are low-voltage warnings for the encoder battery. Positions are still held, so replace the battery while the machine is powered.
  • APC alarm 306. The encoder battery voltage has dropped to zero. Expect to re-establish the reference position on the affected axes.
  • It has been a year. FANUC maintenance manuals call for replacing both batteries on a yearly schedule, whether or not a warning has appeared. Putting it on the preventive maintenance calendar is the simplest way to never see alarm 300.

Key takeaway

Replace FANUC batteries with control power on

With the control powered, memory and encoder positions run off the machine, not the battery, so you can unplug the old cell without losing anything. Pull it with the power off and you are relying on a short capacitor backup, or nothing at all.

Back up before you touch anything

Even a careful swap can go wrong: a dropped connector, a bad new cell, an unexpected power cut. A current backup turns a lost-memory event into a 20-minute restore.

1
Take a full SRAM backup to a memory card. On i-series controls, power up while holding the two right-most soft keys to open the BOOT screen, choose SRAM DATA UTILITY, then SRAM BACKUP. This saves the whole memory image in one file.
2
Save parameters and programs as text files too. From the ALL IO screen, punch out the CNC parameters, part programs, tool offsets, pitch error compensation and macro variables. Text files can be read and restored selectively; the SRAM image cannot.
3
Write down the machine builder's parameter sheet location. If both backups fail, the builder's original sheet is your last resort.

Replace the control memory battery

This is the procedure for most 16i, 18i and 21i-B controls. Check your control's maintenance manual for the exact battery position on your model.

Safety

This work is done inside a live cabinet. It should be done by qualified maintenance staff, with the machine in E-stop, servo power off where your procedure allows, and normal electrical safety and ESD precautions in place.

1
Have the new battery in hand. Match the connector and voltage to the old one before you start.
2
Keep the control powered on for about 30 seconds, then press E-stop. Leave control power on for the rest of the job.
3
Open the battery cover on the control unit and locate the battery and its connector.
4
Unplug the old battery and plug in the new one. Hold the connector body, not the wires, and work without a long pause between the two.
5
Seat the battery in its holder and close the cover. Make sure the lead is not pinched.
6
Confirm the BAT warning has cleared and spot-check a few parameters and a program against your backup.

Replace the APC (encoder) battery

The same rule applies: power on. On alpha i amplifiers the 6 V lithium pack sits in the front of the amplifier; on older systems the D-cells sit in a separate battery case.

1
Power on the control and put the machine in E-stop. The encoders stay powered from the amplifiers while you work.
2
Remove the battery cover on the amplifier or the battery case.
3
Swap the battery or cells. For a D-cell case, replace all four cells at once with fresh batteries from the same pack, and check the polarity.
4
Refit the cover and clear the alarm. Alarms 307 and 308 should reset once voltage is back.

In stock at IAC

Replacement CNC and PLC backup batteries

GE Fanuc, Panasonic, Toshiba and more, including Panasonic BR-2/3AGCT4A packs. Find your battery by model.

Shop batteries

If memory or position was lost

Lost parameters or programs

If the control powers up with cleared memory, alarms or a blank parameter screen, restore the SRAM image from the BOOT screen using SRAM RESTORE, then cycle power. If you only have text backups, load the parameters first, cycle power, then load offsets, pitch error compensation, macro variables and programs. Without any backup, you will need the machine builder's parameter sheet and their support line.

Alarm 300: reference return needed

If the encoder battery died or was removed with the power off, the affected axes lose their absolute position and the control raises alarm 300. Depending on how the machine was set up, that means a reference return with dogs or re-setting the reference position by hand. Follow the machine builder's procedure here: an incorrect reference position can cause a crash or an over-travel.

Plan ahead

Keep a spare control battery and an APC battery for every FANUC machine on the floor. They cost little and they turn a BAT warning on a Friday afternoon into a ten-minute job instead of a weekend outage.

FAQ

Can I replace a FANUC battery with the power off?

FANUC's procedure is to replace both the control memory battery and the APC battery with control power on. Some controls hold memory briefly on a capacitor, but relying on it is a gamble. Back up first and keep the power on.

How long does a FANUC CNC battery last?

Plan on replacing both batteries every year. Lithium cells often last longer, but a yearly swap on the preventive maintenance schedule is far cheaper than a recovery.

Is there an equivalent battery to the FANUC original?

Yes, for many models. Match the chemistry, voltage, capacity and connector. Our upcoming controller battery cross-reference lists ER6V, BR-2/3A and common equivalents.

What do APC alarms 306, 307 and 308 mean?

They are encoder battery alarms on i-series controls. 307 and 308 are low-voltage warnings; 306 means the voltage has dropped to zero. Replace the battery with power on as soon as 307 or 308 appears.

Need a FANUC battery on the line this week?

We stock replacement batteries for GE Fanuc, Panasonic, Toshiba and more, with same-day shipping and a 2-year warranty. Send us the model and we will match it.