Close

Successfully Added

The product is added to your quote.

Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners
Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners
Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners
  • Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners
  • Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners

Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners

SKU: KA6C9HL48LV

Estimated delivery: September 10th - September 12th

Order for next-day shipment.

This product is not available for online purchase.

Use the Request a quote to get the pricing

K2A6C9HL48LV-50HZ
Available
Request a quote
K2A6C9HL48LV-60HZ
Available
Request a quote
KA6C9HL48LV
Available
Request a quote

Description

The Hazardous Location Series HL48LV air conditioner is engineered to deliver reliable climate control in Class 1 Division 1 and 2 hazardous locations while maintaining the safety and integrity of sensitive electrical equipment. All models are UL Listed per UL 484 for Special Purpose Air Conditioners and UL Recognized per NFPA 496:2013 for Purged and Pressurized Enclosures, meeting NEC Class I Division 1 Groups A, B, C, and D when used with an approved Type X Purge System, and Class I Division 2 Groups A, B, C, and D with an approved Type Z Purge System. The unit achieves T-4 temperature classification at 275F/135C and is CE Compliant, ensuring compliance with international standards for hazardous area installations.

The HL48LV utilizes a closed-loop cooling design that completely isolates the enclosure interior airflow system from ambient airflow, preventing contaminated outside air from infiltrating the sensitive component compartment while maintaining precise dehumidification. A compressor short cycle protector safeguards against damage from frequent starting cycles that can occur due to fluctuating heat loads, power interruptions, or solar gain conditions, thereby extending compressor life and reducing maintenance costs. Multi-layer corrugated aluminum filters capture airborne contaminants before they reach internal components, with replacement filters readily available online. Programmable thermostat and temperature alarm functions provide precise thermal management and early warning alerts, while a pressure compensation terminal block enables auxiliary pressure supply connections for enhanced operational flexibility.

Built for durability in demanding industrial environments, the HL48LV maintains NEMA Type 12, 3R, and 4/4X enclosure ratings with painted condenser and evaporator coils for standard corrosion resistance. Internal corrosion protection with an air-cured coating on brazed refrigeration joints is standard on NEMA 4X models, withstanding 1000 hours of salt spray per ASTM B 117. Optional stainless steel shell construction is available for severe corrosive applications. The unit incorporates shock and vibration resistance rated for 4 hours per plane at 1G acceleration in two different planes, and operates on R410a refrigerant with zero ozone depleting potential, supporting environmental compliance and sustainable operations.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    KA6C9HL48LV KA6C9HL48LV 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
    K2A6C9HL48LV-60HZ K2A6C9HL48LV-60HZ 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
    K2A6C9HL48LV-50HZ K2A6C9HL48LV-50HZ 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The Hazardous Location Series HL48LV air conditioner is engineered to deliver reliable climate control in Class 1 Division 1 and 2 hazardous locations while maintaining the safety and integrity of sensitive electrical equipment. All models are UL Listed per UL 484 for Special Purpose Air Conditioners and UL Recognized per NFPA 496:2013 for Purged and Pressurized Enclosures, meeting NEC Class I Division 1 Groups A, B, C, and D when used with an approved Type X Purge System, and Class I Division 2 Groups A, B, C, and D with an approved Type Z Purge System. The unit achieves T-4 temperature classification at 275F/135C and is CE Compliant, ensuring compliance with international standards for hazardous area installations.

    The HL48LV utilizes a closed-loop cooling design that completely isolates the enclosure interior airflow system from ambient airflow, preventing contaminated outside air from infiltrating the sensitive component compartment while maintaining precise dehumidification. A compressor short cycle protector safeguards against damage from frequent starting cycles that can occur due to fluctuating heat loads, power interruptions, or solar gain conditions, thereby extending compressor life and reducing maintenance costs. Multi-layer corrugated aluminum filters capture airborne contaminants before they reach internal components, with replacement filters readily available online. Programmable thermostat and temperature alarm functions provide precise thermal management and early warning alerts, while a pressure compensation terminal block enables auxiliary pressure supply connections for enhanced operational flexibility.

    Built for durability in demanding industrial environments, the HL48LV maintains NEMA Type 12, 3R, and 4/4X enclosure ratings with painted condenser and evaporator coils for standard corrosion resistance. Internal corrosion protection with an air-cured coating on brazed refrigeration joints is standard on NEMA 4X models, withstanding 1000 hours of salt spray per ASTM B 117. Optional stainless steel shell construction is available for severe corrosive applications. The unit incorporates shock and vibration resistance rated for 4 hours per plane at 1G acceleration in two different planes, and operates on R410a refrigerant with zero ozone depleting potential, supporting environmental compliance and sustainable operations.

  • Documentation

    AI Product Assistant

    Ask questions about Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners

    AI Assistant

    Ask questions about Hazardous Location Series HL48LVClass 1 Division 1 and 2 Air Conditioners

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the Location, we offer hundreds of Hazardous parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your Hazardous replacement parts today.

Contact Us