Description

The "On-Off Primary Burner Control" from Honeywell is designed with an intermittent pilot type, making it suitable for power requirements of 120 VAC at a standard frequency of 50/60 Hz. This unit operates with an intermittent main flame establishing period and offers a choice in pilot flame establishing period, selectable between 4 and 10 seconds.

The On-Off Burner Control ensures comprehensive functionality, automatically orchestrating burner sequencing and providing optimal flame supervision. For added convenience, it showcases system status and conducts system or self-diagnostics for efficient troubleshooting.

Please note, a subbase and amplifier are required to operate this Honeywell device. Additional options such as a Modbus interface, keyboard display module, or remote display module can be integrated to enhance system compatibility and control. Five built-in LEDs provide clear sequence information, and the plug-in amplifiers are fully interchangeable.

The Burner Control also allows for local or remote annunciation of operational and fault information, granting users the option to receive critical system updates remotely. After a power outage, the unit's non-volatile memory retains all history files and lockout status information, ensuring no data loss. Users can also select the relight or lockout option in case of flame loss.

This model functions optimally in harsh environments and can withstand operating temperatures ranging from -40 F to 140 F. It markets the essential capabilities of an "On-Off Primary Control" in the field of industrial automation and control systems.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    IAC Certified Refurbished RM7890A1015-R 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The "On-Off Primary Burner Control" from Honeywell is designed with an intermittent pilot type, making it suitable for power requirements of 120 VAC at a standard frequency of 50/60 Hz. This unit operates with an intermittent main flame establishing period and offers a choice in pilot flame establishing period, selectable between 4 and 10 seconds.

    The On-Off Burner Control ensures comprehensive functionality, automatically orchestrating burner sequencing and providing optimal flame supervision. For added convenience, it showcases system status and conducts system or self-diagnostics for efficient troubleshooting.

    Please note, a subbase and amplifier are required to operate this Honeywell device. Additional options such as a Modbus interface, keyboard display module, or remote display module can be integrated to enhance system compatibility and control. Five built-in LEDs provide clear sequence information, and the plug-in amplifiers are fully interchangeable.

    The Burner Control also allows for local or remote annunciation of operational and fault information, granting users the option to receive critical system updates remotely. After a power outage, the unit's non-volatile memory retains all history files and lockout status information, ensuring no data loss. Users can also select the relight or lockout option in case of flame loss.

    This model functions optimally in harsh environments and can withstand operating temperatures ranging from -40 F to 140 F. It markets the essential capabilities of an "On-Off Primary Control" in the field of industrial automation and control systems.

  • Documentation

    AI Product Assistant

    Ask questions about Honeywell RM7890A1015

    AI Assistant

    Ask questions about Honeywell RM7890A1015

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the RM7890A1015, we offer hundreds of Honeywell parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your Honeywell replacement parts today.

Contact Us