Fermer

Ajouté avec succès

Le produit a été ajouté à votre devis.

WEG 14417196 Alternator
WEG 14417196 Alternator

WEG 14417196 GTA201AIHE IP23 B15T SAE 5/SAE 8

SKU : 14417196-FS

Livraison estimée : September 27th - September 29th

Commandez maintenant pour une expédition le lendemain.

Ce produit n’est pas disponible à l’achat en ligne.

Utilisez « Demander un devis » pour obtenir le prix

New
Disponible
Demander un devis

Description

The WEG 14417196 is a G Plus-line brushless synchronous alternator for industrial generator sets. WEG lists it as “GTA201AIHE IP23 B15T SAE 5/SAE 8”. Key specifications: model GTA201AIHE, frame (IEC) 200.0, number of poles 4, rated speed - 60 Hz 1800 rpm.

Drawing on WEG's deep design and manufacturing experience, the G Plus Line of Alternators is a modern, world-class range of brushless synchronous alternators for the global market. It serves a broad set of continuous, prime and standby applications across industrial, agriculture, marine, commercial, mining, healthcare and other sectors.

WEG 14417196 Technical Specifications

Manufacturer WEG
WEG material number 14417196
WEG designation GTA201AIHE IP23 B15T SAE 5/SAE 8
Product type Alternator
Series G Plus
Alternators for Generator Sets
Degree of Protection IP23
Cooling IC01
Excitation System Brushless with Auxiliary Coil
Mounting B15T
Coupling disc SAE 8
Flange Type SAE 5
Type of Pole Salient
Insulation Class 180°C (H)
Frame (IEC) 200.0
Painting Plan 207A
Operation mode NETWORK PARALLEL OPERATION
Finish Color MATTE BLACK
Voltage Regulator Inside of main terminal box
Standard IEC/NEMA
Model GTA201AIHE
THD (L-L, no load) ≤ 3%
Altitude up to 1000 m.a.s.l
Stator winding pitch 2/3
Number of Leads 12
Power Factor 0.8 to 1.0
Number of poles 4
Rated speed - 50 Hz 1500 rpm
Rated speed - 60 Hz 1800 rpm
Overspeed 2250 rpm
Approx. weight 281 kg
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Voltages (V)
Y (series star) connection 380 V
YY (parallel star) connection 190 V
Δ (series delta) connection 220 V
ΔΔ (parallel delta) connection 110 V
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Output power (kVA)
Continuous 80/40 51.0
Continuous 105/40 59.0
Continuous 125/40 70.0
Standby 150/40 72.0
Standby 163/27 74.0
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 305.5%
X'd Direct axis transient reactance 25.2%
X''d Direct axis subtransient reactance 21.6%
Xq Quadrature axis sync. reactance 116.2%
X''q Quadrature axis subtrans. reactance 19.4%
X2 Negative sequence reactance 20.4%
X0 Zero sequence reactance 3.6%
T'd Direct axis trans. short circ. time constant 61.9ms
T''d Direct axis sub. short circ. time constant 1.0ms
T'do Transient open circuit time constant 762ms
T''do Subtrans. constant ofopened circuit 1.2ms
Ta Short circuit time const. of armature 9ms
uc Full load excitation voltage 39.3V
ic Full load excitation current 4.1A
ic No load excitation current 0.7A
Icc Sustained short-circuit current 319A
Kcc Short-circuit ratio 0.36
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 1 (3~ - 50Hz - 380/190/220/110 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Voltages (V)
Y (series star) connection 400 V
YY (parallel star) connection 200 V
Δ (series delta) connection 230 V
ΔΔ (parallel delta) connection 115 V
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Output power (kVA)
Continuous 80/40 51.0
Continuous 105/40 59.0
Continuous 125/40 70.0
Standby 150/40 72.0
Standby 163/27 74.0
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 276.1%
X'd Direct axis transient reactance 22.8%
X''d Direct axis subtransient reactance 19.6%
Xq Quadrature axis sync. reactance 105.0%
X''q Quadrature axis subtrans. reactance 17.5%
X2 Negative sequence reactance 18.4%
X0 Zero sequence reactance 3.3%
T'd Direct axis trans. short circ. time constant 62.0ms
T''d Direct axis sub. short circ. time constant 1.0ms
T'do Transient open circuit time constant 763ms
T''do Subtrans. constant ofopened circuit 1.2ms
Ta Short circuit time const. of armature 9ms
uc Full load excitation voltage 40.1V
ic Full load excitation current 4.2A
ic No load excitation current 0.8A
Icc Sustained short-circuit current 303A
Kcc Short-circuit ratio 0.42
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 2 (3~ - 50Hz - 400/200/230/115 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 3 (1~ - 50Hz - 190-200 V) – Voltages (V)
Single phase low zig-zag or single phase delta 190-200 V
Model 3 (1~ - 50Hz - 190-200 V) – Output power (kVA)
Continuous 80/40 32.3
Continuous 105/40 36.9
Continuous 125/40 40.4
Standby 150/40 44.3
Standby 163/27 46.1
Model 3 (1~ - 50Hz - 190-200 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 407.3%
X'd Direct axis transient reactance 33.6%
X''d Direct axis subtransient reactance 28.9%
Xq Quadrature axis sync. reactance 154.9%
X''q Quadrature axis subtrans. reactance 25.8%
X2 Negative sequence reactance 27.2%
X0 Zero sequence reactance 4.8%
T'd Direct axis trans. short circ. time constant 82.5ms
T''d Direct axis sub. short circ. time constant 1.3ms
T'do Transient open circuit time constant 1015ms
T''do Subtrans. constant ofopened circuit 1.6ms
Ta Short circuit time const. of armature 12ms
uc Full load excitation voltage 39.3V
ic Full load excitation current 4.1A
ic No load excitation current 0.9A
Icc Sustained short-circuit current 303A
Kcc Short-circuit ratio 0.48
Model 3 (1~ - 50Hz - 190-200 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 3 (1~ - 50Hz - 190-200 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Voltages (V)
Y (series star) connection 380 V
YY (parallel star) connection 190 V
Δ (series delta) connection 220 V
ΔΔ (parallel delta) connection 110 V
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Output power (kVA)
Continuous 80/40 62.1
Continuous 105/40 71.2
Continuous 125/40 80.0
Standby 150/40 83.0
Standby 163/27 86.4
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 388.8%
X'd Direct axis transient reactance 32.2%
X''d Direct axis subtransient reactance 27.6%
Xq Quadrature axis sync. reactance 147.8%
X''q Quadrature axis subtrans. reactance 24.7%
X2 Negative sequence reactance 26.1%
X0 Zero sequence reactance 4.6%
T'd Direct axis trans. short circ. time constant 61.8ms
T''d Direct axis sub. short circ. time constant 1.0ms
T'do Transient open circuit time constant 757ms
T''do Subtrans. constant ofopened circuit 1.2ms
Ta Short circuit time const. of armature 9ms
uc Full load excitation voltage 34.5V
ic Full load excitation current 3.6A
ic No load excitation current 0.4A
Icc Sustained short-circuit current 365A
Kcc Short-circuit ratio 0.26
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 4 (3~ - 60Hz - 380/190/220/110 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Voltages (V)
Y (series star) connection 416 V
YY (parallel star) connection 208 V
Δ (series delta) connection 240 V
ΔΔ (parallel delta) connection 120 V
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Output power (kVA)
Continuous 80/40 64.4
Continuous 105/40 73.8
Continuous 125/40 84.7
Standby 150/40 90.0
Standby 163/27 92.6
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 345.1%
X'd Direct axis transient reactance 28.5%
X''d Direct axis subtransient reactance 24.5%
Xq Quadrature axis sync. reactance 133.1%
X''q Quadrature axis subtrans. reactance 35.6%
X2 Negative sequence reactance 30.0%
X0 Zero sequence reactance 4.1%
T'd Direct axis trans. short circ. time constant 70.8ms
T''d Direct axis sub. short circ. time constant 1.2ms
T'do Transient open circuit time constant 883ms
T''do Subtrans. constant ofopened circuit 1.5ms
Ta Short circuit time const. of armature 10ms
uc Full load excitation voltage 37.5V
ic Full load excitation current 3.9A
ic No load excitation current 0.6A
Icc Sustained short-circuit current 323A
Kcc Short-circuit ratio 0.3
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 5 (3~ - 60Hz - 416/208/240/120 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Voltages (V)
Y (series star) connection 440 V
YY (parallel star) connection 220 V
Δ (series delta) connection 254 V
ΔΔ (parallel delta) connection 127 V
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Output power (kVA)
Continuous 80/40 66.0
Continuous 105/40 75.6
Continuous 125/40 88.0
Standby 150/40 95.0
Standby 163/27 97.0
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 320.5%
X'd Direct axis transient reactance 26.4%
X''d Direct axis subtransient reactance 22.7%
Xq Quadrature axis sync. reactance 121.9%
X''q Quadrature axis subtrans. reactance 20.3%
X2 Negative sequence reactance 21.4%
X0 Zero sequence reactance 3.8%
T'd Direct axis trans. short circ. time constant 61.9ms
T''d Direct axis sub. short circ. time constant 1.0ms
T'do Transient open circuit time constant 761ms
T''do Subtrans. constant ofopened circuit 1.2ms
Ta Short circuit time const. of armature 9ms
uc Full load excitation voltage 36.4V
ic Full load excitation current 3.8A
ic No load excitation current 0.6A
Icc Sustained short-circuit current 346A
Kcc Short-circuit ratio 0.33
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 6 (3~ - 60Hz - 440/220/254/127 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Voltages (V)
Y (series star) connection 480 V
YY (parallel star) connection 240 V
Δ (series delta) connection 277 V
ΔΔ (parallel delta) connection 138 V
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Output power (kVA)
Continuous 80/40 66.1
Continuous 105/40 75.7
Continuous 125/40 88.0
Standby 150/40 95.0
Standby 163/27 97.0
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 270.0%
X'd Direct axis transient reactance 22.2%
X''d Direct axis subtransient reactance 19.1%
Xq Quadrature axis sync. reactance 102.7%
X''q Quadrature axis subtrans. reactance 17.1%
X2 Negative sequence reactance 18.0%
X0 Zero sequence reactance 3.2%
T'd Direct axis trans. short circ. time constant 62.0ms
T''d Direct axis sub. short circ. time constant 1.0ms
T'do Transient open circuit time constant 763ms
T''do Subtrans. constant ofopened circuit 1.2ms
Ta Short circuit time const. of armature 9ms
uc Full load excitation voltage 37.5V
ic Full load excitation current 3.9A
ic No load excitation current 0.8A
Icc Sustained short-circuit current 318A
Kcc Short-circuit ratio 0.43
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 7 (3~ - 60Hz - 480/240/277/138 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
Model 8 (1~ - 60Hz - 220-240 V) – Voltages (V)
Single phase low zig-zag or single phase delta 220-240 V
Model 8 (1~ - 60Hz - 220-240 V) – Output power (kVA)
Continuous 80/40 38.7
Continuous 105/40 44.4
Continuous 125/40 48.4
Standby 150/40 53.0
Standby 163/27 55.3
Model 8 (1~ - 60Hz - 220-240 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
Xd Direct axis synchronous reactance 427.3%
X'd Direct axis transient reactance 35.3%
X''d Direct axis subtransient reactance 30.3%
Xq Quadrature axis sync. reactance 162.5%
X''q Quadrature axis subtrans. reactance 27.1%
X2 Negative sequence reactance 28.6%
X0 Zero sequence reactance 5.0%
T'd Direct axis trans. short circ. time constant 82.5ms
T''d Direct axis sub. short circ. time constant 1.3ms
T'do Transient open circuit time constant 1014ms
T''do Subtrans. constant ofopened circuit 1.6ms
Ta Short circuit time const. of armature 12ms
uc Full load excitation voltage 36.4V
ic Full load excitation current 3.8A
ic No load excitation current 0.8A
Icc Sustained short-circuit current 302A
Kcc Short-circuit ratio 0.44
Model 8 (1~ - 60Hz - 220-240 V) – Automatic voltage regulator data
Voltage Regulator Inside of main terminal box
Voltage regulator model OPT-06 5A AM/220M E9 PAR5
Accuracy (stability) +/- 0.5%
Rated current 5 A
Analog input. Yes
Digital input No
Peak current 7 A/10 s
Droop / TC Yes
Dynamic recovery 8 to 500 ms
U/F Yes
Internal voltage adjustment +/- 15%
External voltage adjustment +/- 10%
Transient recovery time for ΔU=20% 500 ms
Model 8 (1~ - 60Hz - 220-240 V) – Other characteristics
Air flow 0.9 m³/s
Exciter stator winding resistance at 20ºC 10.55 ohm
Stator winding resistance at 20ºC 0.09886 ohm
Rotor winding resistance 0.98 ohm
Stator winding layers 2
Inertia WR² 0.49 kgm²
NDE Bearing 6210-2RS
Coupling disc SAE 8
Flange Type SAE 5
Driving Machine Diesel engine
WEG catalog category Generation,Transmission and Distribution > Generators > Alternators for Generator Sets > Industrial > G Plus Line

Industrial Automation Co. offers the WEG 14417196 in new condition. Request a quote for current pricing, availability, and lead time.

Autres options de paiement

Options de paiement sécurisées

  • Réponse garantie sous 24 heures

    Envoyez une demande de devis et recevez rapidement un devis fiable de notre équipe afin de maintenir vos opérations en cours.

    En savoir plus sur l’expédition
  • Garantie de 24 mois

    Deux fois la norme du secteur — protection complète contre les défauts pendant 2 années entières.

    En savoir plus sur la garantie
  • Plusieurs états disponibles

    Plusieurs options d’approvisionnement pour vous aider à maîtriser les coûts sans compromettre les performances.

    En savoir plus sur la garantie
  • Catalogue complet

    Important stock aux États-Unis et approvisionnement rapide pour Mitsubishi, Siemens, Schneider et de nombreuses autres marques.

    En savoir plus
  • Plus de 65 000 clients nous font confiance

    Des fabricants et des installations dans tout le pays comptent sur nous pour les pièces, les réparations et l’assistance.

    En savoir plus
  • Options d’achat

    Tous les produits sont couverts par la garantie de 2 ans d’Industrial Automation Co.

    État SKU Prix Garantie Disponibilité Quantité Achat
    New 14417196-FS Garantie prolongée de 2 ans Appelez pour vérifier la disponibilité Appelez pour vérifier la disponibilité (877)-727-8757
  • Description

    The WEG 14417196 is a G Plus-line brushless synchronous alternator for industrial generator sets. WEG lists it as “GTA201AIHE IP23 B15T SAE 5/SAE 8”. Key specifications: model GTA201AIHE, frame (IEC) 200.0, number of poles 4, rated speed - 60 Hz 1800 rpm.

    Drawing on WEG's deep design and manufacturing experience, the G Plus Line of Alternators is a modern, world-class range of brushless synchronous alternators for the global market. It serves a broad set of continuous, prime and standby applications across industrial, agriculture, marine, commercial, mining, healthcare and other sectors.

    WEG 14417196 Technical Specifications

    Manufacturer WEG
    WEG material number 14417196
    WEG designation GTA201AIHE IP23 B15T SAE 5/SAE 8
    Product type Alternator
    Series G Plus
    Alternators for Generator Sets
    Degree of Protection IP23
    Cooling IC01
    Excitation System Brushless with Auxiliary Coil
    Mounting B15T
    Coupling disc SAE 8
    Flange Type SAE 5
    Type of Pole Salient
    Insulation Class 180°C (H)
    Frame (IEC) 200.0
    Painting Plan 207A
    Operation mode NETWORK PARALLEL OPERATION
    Finish Color MATTE BLACK
    Voltage Regulator Inside of main terminal box
    Standard IEC/NEMA
    Model GTA201AIHE
    THD (L-L, no load) ≤ 3%
    Altitude up to 1000 m.a.s.l
    Stator winding pitch 2/3
    Number of Leads 12
    Power Factor 0.8 to 1.0
    Number of poles 4
    Rated speed - 50 Hz 1500 rpm
    Rated speed - 60 Hz 1800 rpm
    Overspeed 2250 rpm
    Approx. weight 281 kg
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Voltages (V)
    Y (series star) connection 380 V
    YY (parallel star) connection 190 V
    Δ (series delta) connection 220 V
    ΔΔ (parallel delta) connection 110 V
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Output power (kVA)
    Continuous 80/40 51.0
    Continuous 105/40 59.0
    Continuous 125/40 70.0
    Standby 150/40 72.0
    Standby 163/27 74.0
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 305.5%
    X'd Direct axis transient reactance 25.2%
    X''d Direct axis subtransient reactance 21.6%
    Xq Quadrature axis sync. reactance 116.2%
    X''q Quadrature axis subtrans. reactance 19.4%
    X2 Negative sequence reactance 20.4%
    X0 Zero sequence reactance 3.6%
    T'd Direct axis trans. short circ. time constant 61.9ms
    T''d Direct axis sub. short circ. time constant 1.0ms
    T'do Transient open circuit time constant 762ms
    T''do Subtrans. constant ofopened circuit 1.2ms
    Ta Short circuit time const. of armature 9ms
    uc Full load excitation voltage 39.3V
    ic Full load excitation current 4.1A
    ic No load excitation current 0.7A
    Icc Sustained short-circuit current 319A
    Kcc Short-circuit ratio 0.36
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 1 (3~ - 50Hz - 380/190/220/110 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Voltages (V)
    Y (series star) connection 400 V
    YY (parallel star) connection 200 V
    Δ (series delta) connection 230 V
    ΔΔ (parallel delta) connection 115 V
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Output power (kVA)
    Continuous 80/40 51.0
    Continuous 105/40 59.0
    Continuous 125/40 70.0
    Standby 150/40 72.0
    Standby 163/27 74.0
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 276.1%
    X'd Direct axis transient reactance 22.8%
    X''d Direct axis subtransient reactance 19.6%
    Xq Quadrature axis sync. reactance 105.0%
    X''q Quadrature axis subtrans. reactance 17.5%
    X2 Negative sequence reactance 18.4%
    X0 Zero sequence reactance 3.3%
    T'd Direct axis trans. short circ. time constant 62.0ms
    T''d Direct axis sub. short circ. time constant 1.0ms
    T'do Transient open circuit time constant 763ms
    T''do Subtrans. constant ofopened circuit 1.2ms
    Ta Short circuit time const. of armature 9ms
    uc Full load excitation voltage 40.1V
    ic Full load excitation current 4.2A
    ic No load excitation current 0.8A
    Icc Sustained short-circuit current 303A
    Kcc Short-circuit ratio 0.42
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 2 (3~ - 50Hz - 400/200/230/115 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 3 (1~ - 50Hz - 190-200 V) – Voltages (V)
    Single phase low zig-zag or single phase delta 190-200 V
    Model 3 (1~ - 50Hz - 190-200 V) – Output power (kVA)
    Continuous 80/40 32.3
    Continuous 105/40 36.9
    Continuous 125/40 40.4
    Standby 150/40 44.3
    Standby 163/27 46.1
    Model 3 (1~ - 50Hz - 190-200 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 407.3%
    X'd Direct axis transient reactance 33.6%
    X''d Direct axis subtransient reactance 28.9%
    Xq Quadrature axis sync. reactance 154.9%
    X''q Quadrature axis subtrans. reactance 25.8%
    X2 Negative sequence reactance 27.2%
    X0 Zero sequence reactance 4.8%
    T'd Direct axis trans. short circ. time constant 82.5ms
    T''d Direct axis sub. short circ. time constant 1.3ms
    T'do Transient open circuit time constant 1015ms
    T''do Subtrans. constant ofopened circuit 1.6ms
    Ta Short circuit time const. of armature 12ms
    uc Full load excitation voltage 39.3V
    ic Full load excitation current 4.1A
    ic No load excitation current 0.9A
    Icc Sustained short-circuit current 303A
    Kcc Short-circuit ratio 0.48
    Model 3 (1~ - 50Hz - 190-200 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 3 (1~ - 50Hz - 190-200 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Voltages (V)
    Y (series star) connection 380 V
    YY (parallel star) connection 190 V
    Δ (series delta) connection 220 V
    ΔΔ (parallel delta) connection 110 V
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Output power (kVA)
    Continuous 80/40 62.1
    Continuous 105/40 71.2
    Continuous 125/40 80.0
    Standby 150/40 83.0
    Standby 163/27 86.4
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 388.8%
    X'd Direct axis transient reactance 32.2%
    X''d Direct axis subtransient reactance 27.6%
    Xq Quadrature axis sync. reactance 147.8%
    X''q Quadrature axis subtrans. reactance 24.7%
    X2 Negative sequence reactance 26.1%
    X0 Zero sequence reactance 4.6%
    T'd Direct axis trans. short circ. time constant 61.8ms
    T''d Direct axis sub. short circ. time constant 1.0ms
    T'do Transient open circuit time constant 757ms
    T''do Subtrans. constant ofopened circuit 1.2ms
    Ta Short circuit time const. of armature 9ms
    uc Full load excitation voltage 34.5V
    ic Full load excitation current 3.6A
    ic No load excitation current 0.4A
    Icc Sustained short-circuit current 365A
    Kcc Short-circuit ratio 0.26
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 4 (3~ - 60Hz - 380/190/220/110 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Voltages (V)
    Y (series star) connection 416 V
    YY (parallel star) connection 208 V
    Δ (series delta) connection 240 V
    ΔΔ (parallel delta) connection 120 V
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Output power (kVA)
    Continuous 80/40 64.4
    Continuous 105/40 73.8
    Continuous 125/40 84.7
    Standby 150/40 90.0
    Standby 163/27 92.6
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 345.1%
    X'd Direct axis transient reactance 28.5%
    X''d Direct axis subtransient reactance 24.5%
    Xq Quadrature axis sync. reactance 133.1%
    X''q Quadrature axis subtrans. reactance 35.6%
    X2 Negative sequence reactance 30.0%
    X0 Zero sequence reactance 4.1%
    T'd Direct axis trans. short circ. time constant 70.8ms
    T''d Direct axis sub. short circ. time constant 1.2ms
    T'do Transient open circuit time constant 883ms
    T''do Subtrans. constant ofopened circuit 1.5ms
    Ta Short circuit time const. of armature 10ms
    uc Full load excitation voltage 37.5V
    ic Full load excitation current 3.9A
    ic No load excitation current 0.6A
    Icc Sustained short-circuit current 323A
    Kcc Short-circuit ratio 0.3
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 5 (3~ - 60Hz - 416/208/240/120 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Voltages (V)
    Y (series star) connection 440 V
    YY (parallel star) connection 220 V
    Δ (series delta) connection 254 V
    ΔΔ (parallel delta) connection 127 V
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Output power (kVA)
    Continuous 80/40 66.0
    Continuous 105/40 75.6
    Continuous 125/40 88.0
    Standby 150/40 95.0
    Standby 163/27 97.0
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 320.5%
    X'd Direct axis transient reactance 26.4%
    X''d Direct axis subtransient reactance 22.7%
    Xq Quadrature axis sync. reactance 121.9%
    X''q Quadrature axis subtrans. reactance 20.3%
    X2 Negative sequence reactance 21.4%
    X0 Zero sequence reactance 3.8%
    T'd Direct axis trans. short circ. time constant 61.9ms
    T''d Direct axis sub. short circ. time constant 1.0ms
    T'do Transient open circuit time constant 761ms
    T''do Subtrans. constant ofopened circuit 1.2ms
    Ta Short circuit time const. of armature 9ms
    uc Full load excitation voltage 36.4V
    ic Full load excitation current 3.8A
    ic No load excitation current 0.6A
    Icc Sustained short-circuit current 346A
    Kcc Short-circuit ratio 0.33
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 6 (3~ - 60Hz - 440/220/254/127 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Voltages (V)
    Y (series star) connection 480 V
    YY (parallel star) connection 240 V
    Δ (series delta) connection 277 V
    ΔΔ (parallel delta) connection 138 V
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Output power (kVA)
    Continuous 80/40 66.1
    Continuous 105/40 75.7
    Continuous 125/40 88.0
    Standby 150/40 95.0
    Standby 163/27 97.0
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 270.0%
    X'd Direct axis transient reactance 22.2%
    X''d Direct axis subtransient reactance 19.1%
    Xq Quadrature axis sync. reactance 102.7%
    X''q Quadrature axis subtrans. reactance 17.1%
    X2 Negative sequence reactance 18.0%
    X0 Zero sequence reactance 3.2%
    T'd Direct axis trans. short circ. time constant 62.0ms
    T''d Direct axis sub. short circ. time constant 1.0ms
    T'do Transient open circuit time constant 763ms
    T''do Subtrans. constant ofopened circuit 1.2ms
    Ta Short circuit time const. of armature 9ms
    uc Full load excitation voltage 37.5V
    ic Full load excitation current 3.9A
    ic No load excitation current 0.8A
    Icc Sustained short-circuit current 318A
    Kcc Short-circuit ratio 0.43
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 7 (3~ - 60Hz - 480/240/277/138 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    Model 8 (1~ - 60Hz - 220-240 V) – Voltages (V)
    Single phase low zig-zag or single phase delta 220-240 V
    Model 8 (1~ - 60Hz - 220-240 V) – Output power (kVA)
    Continuous 80/40 38.7
    Continuous 105/40 44.4
    Continuous 125/40 48.4
    Standby 150/40 53.0
    Standby 163/27 55.3
    Model 8 (1~ - 60Hz - 220-240 V) – Electrical data (FP=0.8 / continuous 125/40 (H))
    Xd Direct axis synchronous reactance 427.3%
    X'd Direct axis transient reactance 35.3%
    X''d Direct axis subtransient reactance 30.3%
    Xq Quadrature axis sync. reactance 162.5%
    X''q Quadrature axis subtrans. reactance 27.1%
    X2 Negative sequence reactance 28.6%
    X0 Zero sequence reactance 5.0%
    T'd Direct axis trans. short circ. time constant 82.5ms
    T''d Direct axis sub. short circ. time constant 1.3ms
    T'do Transient open circuit time constant 1014ms
    T''do Subtrans. constant ofopened circuit 1.6ms
    Ta Short circuit time const. of armature 12ms
    uc Full load excitation voltage 36.4V
    ic Full load excitation current 3.8A
    ic No load excitation current 0.8A
    Icc Sustained short-circuit current 302A
    Kcc Short-circuit ratio 0.44
    Model 8 (1~ - 60Hz - 220-240 V) – Automatic voltage regulator data
    Voltage Regulator Inside of main terminal box
    Voltage regulator model OPT-06 5A AM/220M E9 PAR5
    Accuracy (stability) +/- 0.5%
    Rated current 5 A
    Analog input. Yes
    Digital input No
    Peak current 7 A/10 s
    Droop / TC Yes
    Dynamic recovery 8 to 500 ms
    U/F Yes
    Internal voltage adjustment +/- 15%
    External voltage adjustment +/- 10%
    Transient recovery time for ΔU=20% 500 ms
    Model 8 (1~ - 60Hz - 220-240 V) – Other characteristics
    Air flow 0.9 m³/s
    Exciter stator winding resistance at 20ºC 10.55 ohm
    Stator winding resistance at 20ºC 0.09886 ohm
    Rotor winding resistance 0.98 ohm
    Stator winding layers 2
    Inertia WR² 0.49 kgm²
    NDE Bearing 6210-2RS
    Coupling disc SAE 8
    Flange Type SAE 5
    Driving Machine Diesel engine
    WEG catalog category Generation,Transmission and Distribution > Generators > Alternators for Generator Sets > Industrial > G Plus Line

    Industrial Automation Co. offers the WEG 14417196 in new condition. Request a quote for current pricing, availability, and lead time.

  • Documentation

    AI Product Assistant

    Ask questions about WEG 14417196 GTA201AIHE IP23 B15T SAE 5/SAE 8

    Assistant IA

    Posez des questions sur WEG 14417196 GTA201AIHE IP23 B15T SAE 5/SAE 8

    Questions suggérées

Quick search

Envoyez votre article pour une évaluation gratuite et un devis de réparation. Utilisez notre formulaire RMA ou envoyez une demande de réparation à service@iac.us.com, et nous vous contacterons pour évaluer votre situation et vous fournir les informations d’expédition.

Assistance technique

Besoin d’aide pour l’installation, la configuration ou le dépannage ? Nos experts techniques sont à votre disposition.

  • Assistance téléphonique

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Commandez vos pièces d’automatisation industrielle dès aujourd’hui

Industrial Automation Co. est un fournisseur de premier plan de composants de remplacement et de rechange pour l’automatisation industrielle. En plus de 14417196, nous proposons des centaines de pièces WEG actuellement disponibles dans notre entrepôt. La plupart de nos composants d’automatisation sont expédiés le jour même et sont couverts par notre garantie de deux ans. Contactez-nous dès aujourd’hui pour commander vos pièces WEG.

Nous contacter