Description

Yaskawa
Main functionVariable Speed/Frequency Drive (VSD/VFD) / Inverter
Product series / family nameA1000 series
Network frequency(output) 0.01-400 Hz
(input) 50/60 Hz
FunctionsMulti-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter - USA region
Droop Control
Speed/torque Control Switching
Feed Forward Control
Zero servo function
Speed search
Overtorque detection
Undertorque detection
Torque limit
17-step speed
Acceleration/Deceleration time switch
S-curve accel/decel
3-wire sequence
Auto-tuning
Dwell
Cooling fan on/off switch
Slip compensation
Torque compensation
Frequency jump
Upper/lower limits for frequency reference
DC injection braking at start and stop
Overexcitation braking
High slip braking
PID control
Energy saving control
Fault restart
Application presets
Backup
Online tuning
KEB
Overexcitation deceleration
Inertia (ASR) tuning
High Frequency Injection
Supply voltage (AC)380Vac-480Vac (400Vac / 415Vac / 440Vac)
DisplayLED 5-digit display
Type of network3-phase input (3P)
Rated current72A (Normal duty)
60A (heavy duty)
120% / 60s (Normal duty) or 150% / 60s (heavy duty) overload current rating
Rated power (HP)50HP (Normal duty)
40HP (heavy duty)
Protection functionsMotor overheat
Overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss ride-thru
Overheat
Ground fault
Protection settings(Overcurrent) output current exceeds 200% of heavy duty rating
(Overload) 120% of rated output current; normal duty
(Overload) 150% of rated output current; heavy duty
Communication protocolRS-422
RS-485
Mounting modeWall mounting
Digital inputs1 x digital input (24Vdc; Sink/Source) (S1 - Forward / Stop)
1 x digital input (24Vdc; Sink/Source) (S2 - Reverse / Stop)
1 x digital input (24Vdc; Sink/Source) (S3 - External fault)
1 x digital input (24Vdc; Sink/Source) (S4 - Fault reset)
1 x digital input (24Vdc; Sink/Source) (S5 - Multi-step speed 1)
1 x digital input (24Vdc; Sink/Source) (S6 - Multi-step speed 2)
1 x digital input (24Vdc; Sink/Source) (S7 - Jog speed)
1 x digital input (24Vdc; Sink/Source) (S8 - External Baseblock)
1 x digital input (Pulse train input)
Digital outputs1 x digital output (SPDT Single Pole Double Throw contact type) (MA-MB-MC; MC-MB closed means fault)
1 x digital output (NO Normally Open contact type / Multi-function contact output) (M1-M2)
1 x digital output (NO Normally Open contact type / Multi-function contact output (Zero speed) contact) (M3-M4)
1 x digital output (NO Normally Open contact type / Multi-function (Speed agree 1) contact output) (M5-M6)
1 x digital output (multi-function pulse train) (MP)
Analog inputs1 x analog input (-10...+10Vdc / 20kΩ) (Analog Input 1 - Frequency reference bias)
1 x analog input (0-20mA / 4-20mA / -10...+10Vdc / 250Ω) (Analog Input 2 - Frequency reference bias)
1 x analog input (-10...+10Vdc / PTC input) (Analog input 3 - Aux. frequency reference or motor temperature)
Analog outputs1 x analog output (4-20mA / -10...+10Vdc) (FM - to output frequency meter)
1 x analog output (4-20mA / -10...+10Vdc) (AM - to output current meter)
Degree of protectionIP00
Net Height (mm)443 mm
Net Width (mm)283.75 mm
Net Depth (mm)254 mm
Ambient air temperature for storage-20...+60 °C
Technology used in componentForced ventilation (Fan-cooling)
Standard heatsink fins
Integrated DC choke
Rated apparent power (S)55kVA (Normal duty)
48kVA (heavy duty)
Application typeHVAC
Fans
Pumps
Compressors
Conveyors
Machine Tools
Extruders
Punching Presses
Winders
Order code / Manufacturer SKUCIMRAU4A0072AAA
Manufacturer product statusCommercialized
Compliant with standard(s)UL 508C
CSA C22.2
IEC 61508
IEC 61800-5-1

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    New CIMR-AU4A0072AAA 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    Yaskawa
    Main functionVariable Speed/Frequency Drive (VSD/VFD) / Inverter
    Product series / family nameA1000 series
    Network frequency(output) 0.01-400 Hz
    (input) 50/60 Hz
    FunctionsMulti-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter - USA region
    Droop Control
    Speed/torque Control Switching
    Feed Forward Control
    Zero servo function
    Speed search
    Overtorque detection
    Undertorque detection
    Torque limit
    17-step speed
    Acceleration/Deceleration time switch
    S-curve accel/decel
    3-wire sequence
    Auto-tuning
    Dwell
    Cooling fan on/off switch
    Slip compensation
    Torque compensation
    Frequency jump
    Upper/lower limits for frequency reference
    DC injection braking at start and stop
    Overexcitation braking
    High slip braking
    PID control
    Energy saving control
    Fault restart
    Application presets
    Backup
    Online tuning
    KEB
    Overexcitation deceleration
    Inertia (ASR) tuning
    High Frequency Injection
    Supply voltage (AC)380Vac-480Vac (400Vac / 415Vac / 440Vac)
    DisplayLED 5-digit display
    Type of network3-phase input (3P)
    Rated current72A (Normal duty)
    60A (heavy duty)
    120% / 60s (Normal duty) or 150% / 60s (heavy duty) overload current rating
    Rated power (HP)50HP (Normal duty)
    40HP (heavy duty)
    Protection functionsMotor overheat
    Overcurrent
    Overload
    Overvoltage
    Undervoltage
    Momentary power loss ride-thru
    Overheat
    Ground fault
    Protection settings(Overcurrent) output current exceeds 200% of heavy duty rating
    (Overload) 120% of rated output current; normal duty
    (Overload) 150% of rated output current; heavy duty
    Communication protocolRS-422
    RS-485
    Mounting modeWall mounting
    Digital inputs1 x digital input (24Vdc; Sink/Source) (S1 - Forward / Stop)
    1 x digital input (24Vdc; Sink/Source) (S2 - Reverse / Stop)
    1 x digital input (24Vdc; Sink/Source) (S3 - External fault)
    1 x digital input (24Vdc; Sink/Source) (S4 - Fault reset)
    1 x digital input (24Vdc; Sink/Source) (S5 - Multi-step speed 1)
    1 x digital input (24Vdc; Sink/Source) (S6 - Multi-step speed 2)
    1 x digital input (24Vdc; Sink/Source) (S7 - Jog speed)
    1 x digital input (24Vdc; Sink/Source) (S8 - External Baseblock)
    1 x digital input (Pulse train input)
    Digital outputs1 x digital output (SPDT Single Pole Double Throw contact type) (MA-MB-MC; MC-MB closed means fault)
    1 x digital output (NO Normally Open contact type / Multi-function contact output) (M1-M2)
    1 x digital output (NO Normally Open contact type / Multi-function contact output (Zero speed) contact) (M3-M4)
    1 x digital output (NO Normally Open contact type / Multi-function (Speed agree 1) contact output) (M5-M6)
    1 x digital output (multi-function pulse train) (MP)
    Analog inputs1 x analog input (-10...+10Vdc / 20kΩ) (Analog Input 1 - Frequency reference bias)
    1 x analog input (0-20mA / 4-20mA / -10...+10Vdc / 250Ω) (Analog Input 2 - Frequency reference bias)
    1 x analog input (-10...+10Vdc / PTC input) (Analog input 3 - Aux. frequency reference or motor temperature)
    Analog outputs1 x analog output (4-20mA / -10...+10Vdc) (FM - to output frequency meter)
    1 x analog output (4-20mA / -10...+10Vdc) (AM - to output current meter)
    Degree of protectionIP00
    Net Height (mm)443 mm
    Net Width (mm)283.75 mm
    Net Depth (mm)254 mm
    Ambient air temperature for storage-20...+60 °C
    Technology used in componentForced ventilation (Fan-cooling)
    Standard heatsink fins
    Integrated DC choke
    Rated apparent power (S)55kVA (Normal duty)
    48kVA (heavy duty)
    Application typeHVAC
    Fans
    Pumps
    Compressors
    Conveyors
    Machine Tools
    Extruders
    Punching Presses
    Winders
    Order code / Manufacturer SKUCIMRAU4A0072AAA
    Manufacturer product statusCommercialized
    Compliant with standard(s)UL 508C
    CSA C22.2
    IEC 61508
    IEC 61800-5-1

  • Documentation

    AI Product Assistant

    Ask questions about Yaskawa CIMR-AU4A0072AAA

    AI Assistant

    Ask questions about Yaskawa CIMR-AU4A0072AAA

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the CIMR-AU4A0072AAA, we offer hundreds of Yaskawa parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your Yaskawa replacement parts today.

Contact Us