Description

The National Instruments PXI-5900 (Part Number: 780166-01) is a high-performance differential amplifier designed specifically for use with PXI oscilloscope modules, including the PXI-5922. This compact 3U PXI module features two differential input channels that support GND, AC, and DC coupling, along with a software-selectable input impedance of 50 Ω ±2%. The PXI-5900 is equipped with BNC input and SMB output connectors, facilitating seamless integration into various test and measurement systems. It provides an analog input capability with 0.25 ±0.2% vertical gain, a zero input offset error of 500 μV, maintaining 1 dB passband flatness, and achieving a common-mode rejection ratio of 70 dB at 60 Hz. The amplifier boasts a slew rate of 100 V/μs, referencing a balanced differential input, ensuring rapid signal processing.

When paired with the NI PXI-5922, the PXI-5900 accommodates a differential input voltage range of ±20 V (40 V peak-to-peak) and a single-ended output voltage range of ±5 V (10 V peak-to-peak), along with a common-mode input voltage range of ±10 V. Input protection for both 1 MΩ and 50 Ω impedance can withstand ±120 V and 14 Vrms, respectively, with peak voltages remaining below 20 V. Optimized for ease of use, the PXI-5900 is compatible with the NI-SCOPE 3.5.1 IVI-compliant driver, which enables comprehensive control, configuration, and calibration. Additionally, the NI Measurement & Automation Explorer (MAX) software, included on the NI-SCOPE DVD, provides user-friendly configuration and testing tools.

Measuring 21.6 cm x 2.0 cm x 13.0 cm and weighing approximately 173 grams (6.1 oz), the PXI-5900 is an efficient choice for demanding applications. It requires about 15 minutes for a complete warm-up. A detailed user manual and maintenance manual are available for download to support users in maximizing the performance of this differential amplifier. For pricing, please contact a sales representative directly.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title PXI-5900 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The National Instruments PXI-5900 (Part Number: 780166-01) is a high-performance differential amplifier designed specifically for use with PXI oscilloscope modules, including the PXI-5922. This compact 3U PXI module features two differential input channels that support GND, AC, and DC coupling, along with a software-selectable input impedance of 50 Ω ±2%. The PXI-5900 is equipped with BNC input and SMB output connectors, facilitating seamless integration into various test and measurement systems. It provides an analog input capability with 0.25 ±0.2% vertical gain, a zero input offset error of 500 μV, maintaining 1 dB passband flatness, and achieving a common-mode rejection ratio of 70 dB at 60 Hz. The amplifier boasts a slew rate of 100 V/μs, referencing a balanced differential input, ensuring rapid signal processing.

    When paired with the NI PXI-5922, the PXI-5900 accommodates a differential input voltage range of ±20 V (40 V peak-to-peak) and a single-ended output voltage range of ±5 V (10 V peak-to-peak), along with a common-mode input voltage range of ±10 V. Input protection for both 1 MΩ and 50 Ω impedance can withstand ±120 V and 14 Vrms, respectively, with peak voltages remaining below 20 V. Optimized for ease of use, the PXI-5900 is compatible with the NI-SCOPE 3.5.1 IVI-compliant driver, which enables comprehensive control, configuration, and calibration. Additionally, the NI Measurement & Automation Explorer (MAX) software, included on the NI-SCOPE DVD, provides user-friendly configuration and testing tools.

    Measuring 21.6 cm x 2.0 cm x 13.0 cm and weighing approximately 173 grams (6.1 oz), the PXI-5900 is an efficient choice for demanding applications. It requires about 15 minutes for a complete warm-up. A detailed user manual and maintenance manual are available for download to support users in maximizing the performance of this differential amplifier. For pricing, please contact a sales representative directly.

  • Documentation

    AI Product Assistant

    Ask questions about National Instruments PXI-5900

    AI Assistant

    Ask questions about National Instruments PXI-5900

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the Instruments, we offer hundreds of National parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your National replacement parts today.

Contact Us