Description

The On-Off Primary Control with Prepurge is a highly reliable 120 VAC, 50/60 Hz Honeywell product designed for intermittent pilot type applications. This unit has an intermittent main flame establishing period and provides a 4-second or 10-second pilot flame establishing period. It has been specifically made to work in tandem with the Honeywell's 7800 series amplifiers and includes an ignition cutout feature during PFEP (Pilot Flame Establishing Period).

Key functionalities of this control system include automatic burner sequencing, flame supervision, system status indication, as well as offering integrated system or self-diagnostics and troubleshooting mechanisms. For it to function at full capacity, a subbase, amplifier, and prepurge timer are necessary.

This controller offers an array of optional features including a Modbus interface, a keyboard display module, a remote display module, and a first-out expanded annunciator. Five LEDs are built in to provide sequence information and the plug-in amplifiers are interchangeable. Local or remote annunciation of operation and fault information can be leveraged using the optional S7800 Keyboard Display Module.

Uniquely, this unit features a non-volatile memory that retains history files and lockout status even in instances of power loss. The controller also allows the operator to choose between relight or lockout on loss of flame. Finally, this control is suitable for operating conditions ranging from -40 F to 140 F, making it versatile across diverse industrial environments.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title RM7895A1048/U 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The On-Off Primary Control with Prepurge is a highly reliable 120 VAC, 50/60 Hz Honeywell product designed for intermittent pilot type applications. This unit has an intermittent main flame establishing period and provides a 4-second or 10-second pilot flame establishing period. It has been specifically made to work in tandem with the Honeywell's 7800 series amplifiers and includes an ignition cutout feature during PFEP (Pilot Flame Establishing Period).

    Key functionalities of this control system include automatic burner sequencing, flame supervision, system status indication, as well as offering integrated system or self-diagnostics and troubleshooting mechanisms. For it to function at full capacity, a subbase, amplifier, and prepurge timer are necessary.

    This controller offers an array of optional features including a Modbus interface, a keyboard display module, a remote display module, and a first-out expanded annunciator. Five LEDs are built in to provide sequence information and the plug-in amplifiers are interchangeable. Local or remote annunciation of operation and fault information can be leveraged using the optional S7800 Keyboard Display Module.

    Uniquely, this unit features a non-volatile memory that retains history files and lockout status even in instances of power loss. The controller also allows the operator to choose between relight or lockout on loss of flame. Finally, this control is suitable for operating conditions ranging from -40 F to 140 F, making it versatile across diverse industrial environments.

  • Documentation

    AI Product Assistant

    Ask questions about Honeywell On-Off Primary Control With Prepurge - RM7895A1048/U

    AI Assistant

    Ask questions about Honeywell On-Off Primary Control With Prepurge - RM7895A1048/U

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the On-Off, we offer hundreds of Honeywell parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your Honeywell replacement parts today.

Contact Us