Description

Part Number: IC694ALG390

The IC694ALG390, manufactured by GE Fanuc, is a robust 2-channel analog module designed for use with the Rx3i PacSystem. This module provides two output channels capable of converting digital data into analog signals, refreshing at an approximate update rate of 5 milliseconds. In the event of a CPU reset or entry into stop mode, the outputs can be configured to either revert to a default state or hold the last state. The operational voltage range of the IC694ALG390 spans from -10 to +10 volts, while external voltage requirements range from 18VDC to 30VDC with a permissible ripple of up to 10%. The module’s installation location dictates its power sourcing: when placed in an RX3i Universal Backplane, an external source of isolated +24 VDC is required for operation. In contrast, if positioned within an Expansion Backplane, it can utilize either the isolated +24 VDC from the backplane itself or an externally connected isolated +24 VDC supply. Notably, if the external supply is between 27.5-30 VDC, it will take precedence and supply the load requirements over the isolated 24 VDC system. For optimal performance and to ensure hold last state functionality during backplane power loss, an external power source is advisable. It is recommended that field connections be made using high-quality twisted, shielded instrumentation cable to reduce capacitive loading and electromagnetic interference, with shields grounded at the user terminal connector block. The IC694ALG390 has a maximum output load of 5 mA, a power consumption of 32 mA at +5VDC, and 120 mA at +24VDC, and features factory calibration up to 2.5 mV per count.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title IC694ALG390 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    Part Number: IC694ALG390

    The IC694ALG390, manufactured by GE Fanuc, is a robust 2-channel analog module designed for use with the Rx3i PacSystem. This module provides two output channels capable of converting digital data into analog signals, refreshing at an approximate update rate of 5 milliseconds. In the event of a CPU reset or entry into stop mode, the outputs can be configured to either revert to a default state or hold the last state. The operational voltage range of the IC694ALG390 spans from -10 to +10 volts, while external voltage requirements range from 18VDC to 30VDC with a permissible ripple of up to 10%. The module’s installation location dictates its power sourcing: when placed in an RX3i Universal Backplane, an external source of isolated +24 VDC is required for operation. In contrast, if positioned within an Expansion Backplane, it can utilize either the isolated +24 VDC from the backplane itself or an externally connected isolated +24 VDC supply. Notably, if the external supply is between 27.5-30 VDC, it will take precedence and supply the load requirements over the isolated 24 VDC system. For optimal performance and to ensure hold last state functionality during backplane power loss, an external power source is advisable. It is recommended that field connections be made using high-quality twisted, shielded instrumentation cable to reduce capacitive loading and electromagnetic interference, with shields grounded at the user terminal connector block. The IC694ALG390 has a maximum output load of 5 mA, a power consumption of 32 mA at +5VDC, and 120 mA at +24VDC, and features factory calibration up to 2.5 mV per count.

  • Documentation

    AI Product Assistant

    Ask questions about GE Fanuc IC694ALG390

    AI Assistant

    Ask questions about GE Fanuc IC694ALG390

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the Fanuc, we offer hundreds of GE parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your GE replacement parts today.