The Fuji Electric KDRF2L is a 460/480V low impedance AC line reactor compatible with Fuji FRENIC series variable frequency drives for 50 HP NEC motor ratings (65A rated current) — open (ventilated) construction, UL listed, for installation inside a customer-supplied enclosure.
AC line reactors are strongly recommended — and in some utility agreements required — for all VFD installations. The KDRF2L achieves three critical functions: (1) reduces total harmonic current distortion (THD) at the drive input by up to 50%, helping comply with IEEE 519 harmonic limits; (2) protects the drive's input rectifier and DC bus capacitors from damaging line voltage transients and notching; and (3) improves input power factor, reducing reactive current demand.
Install on the AC input side of the drive — between the circuit breaker and the drive's input terminals. Compatible with FRENIC-Mini, FRENIC-Ace, and FRENIC-MEGA drives. Suitable for pumps, HVAC fans, compressors, and installations near harmonic-sensitive equipment. Open (ventilated) construction, ul listed, for installation inside a customer-supplied enclosure. UL listed.
The Fuji Electric KDRF2L is a 460/480V low impedance AC line reactor compatible with Fuji FRENIC series variable frequency drives for 50 HP NEC motor ratings (65A rated current) — open (ventilated) construction, UL listed, for installation inside a customer-supplied enclosure.
AC line reactors are strongly recommended — and in some utility agreements required — for all VFD installations. The KDRF2L achieves three critical functions: (1) reduces total harmonic current distortion (THD) at the drive input by up to 50%, helping comply with IEEE 519 harmonic limits; (2) protects the drive's input rectifier and DC bus capacitors from damaging line voltage transients and notching; and (3) improves input power factor, reducing reactive current demand.
Install on the AC input side of the drive — between the circuit breaker and the drive's input terminals. Compatible with FRENIC-Mini, FRENIC-Ace, and FRENIC-MEGA drives. Suitable for pumps, HVAC fans, compressors, and installations near harmonic-sensitive equipment. Open (ventilated) construction, ul listed, for installation inside a customer-supplied enclosure. UL listed.