Successfully Added

The product is added to your quote.

National Instruments 779182-01
National Instruments 779182-01

National Instruments 779182-01

SKU: 779182-01

Estimated delivery: July 23rd - July 25th

Order for next-day shipment.

This product is not available for online purchase.

Use the Request a quote to get the pricing

Default Title
Available
Request a quote

Description

The National Instruments 779182-01, also known as the PXI-4224, is an isolated analog input module designed for precision measurement applications. This module features eight differential analog input channels with a 16-bit resolution, ensuring high-quality data acquisition. It supports an input voltage range of ±10 VDC, with a maximum sampling rate of 200 kS/s, facilitating efficient data collection across various scenarios. The 779182-01 integrates channel-to-channel isolation, providing 60 VDC (42 Vrms) CAT I isolation, which enhances measurement reliability even in the presence of high common-mode voltages. The module is well-suited for tasks such as isolated thermocouple measurements, multichannel data logging, and testing of fuels and batteries.

The module allows for programmable gain settings on a per-channel basis, optimizing measurement accuracy. Signal connections can be conveniently made using the TB-2725 terminal block or a 25-pin D-SUB for custom configurations. To connect a ground-referenced signal source, simply attach the signal (V+) to the 779182-01 channel input (AI X +) and the reference (V–) to the channel reference (AI X –). Employing proper shielding around the wiring helps minimize noise from capacitive or electrical coupling. Furthermore, using the NI-DAQmx software, users can leverage the DAQmxAdjust4224Cal function to modify the internal and external calibration constants of the SCMP pod; this function requires a known voltage input to operate correctly. Although the National Instruments 779182-01 has been marked obsolete, it remains available for purchase or repair services through Apex Waves.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title 779182-01 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The National Instruments 779182-01, also known as the PXI-4224, is an isolated analog input module designed for precision measurement applications. This module features eight differential analog input channels with a 16-bit resolution, ensuring high-quality data acquisition. It supports an input voltage range of ±10 VDC, with a maximum sampling rate of 200 kS/s, facilitating efficient data collection across various scenarios. The 779182-01 integrates channel-to-channel isolation, providing 60 VDC (42 Vrms) CAT I isolation, which enhances measurement reliability even in the presence of high common-mode voltages. The module is well-suited for tasks such as isolated thermocouple measurements, multichannel data logging, and testing of fuels and batteries.

    The module allows for programmable gain settings on a per-channel basis, optimizing measurement accuracy. Signal connections can be conveniently made using the TB-2725 terminal block or a 25-pin D-SUB for custom configurations. To connect a ground-referenced signal source, simply attach the signal (V+) to the 779182-01 channel input (AI X +) and the reference (V–) to the channel reference (AI X –). Employing proper shielding around the wiring helps minimize noise from capacitive or electrical coupling. Furthermore, using the NI-DAQmx software, users can leverage the DAQmxAdjust4224Cal function to modify the internal and external calibration constants of the SCMP pod; this function requires a known voltage input to operate correctly. Although the National Instruments 779182-01 has been marked obsolete, it remains available for purchase or repair services through Apex Waves.

  • Documentation

    AI Product Assistant

    Ask questions about National Instruments 779182-01

    AI Assistant

    Ask questions about National Instruments 779182-01

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the Instruments, we offer hundreds of National parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your National replacement parts today.