The National Instruments SCXI-1102 is a 32-channel Voltage Input Module designed for high-accuracy voltage and thermocouple measurements. This module features hardware scanning capability for cold-junction sensors and offers DC input coupling with a 2 Hz bandwidth. Each channel is protected against overvoltage with a tolerance of ±42 V and supports a maximum sampling rate of 333 kS/s. Due to its 2 Hz bandwidth, users must allow approximately 3 seconds after making gain adjustments to achieve accurate readings. The SCXI-1102 can process millivolt and volt signals, as well as current inputs ranging from 0 to 20 mA and 4 to 0 mA. It is also compatible with signals from RTDs when used in conjunction with an SCXI-1581 excitation source. The module is designed to work seamlessly with various terminal blocks including the SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, and TBX-96. For precision in thermocouple applications, the SCXI-1303 is recommended. To operate the SCXI-1102, an SCXI chassis or PXI/SCXI combination chassis, an SCXI-1600 or E/M Series DAQ device, and appropriate cabling, connectors, and sensors are required. Users can develop applications using NI-DAQmx driver software and additional environments such as LabVIEW, LabWindows/CVI, or Measurement Studio. The SCXI-1102 is equipped with a 96-pin male DIN C connector and a 50-pin male ribbon cable rear connector. The module has a physical dimension of 1.2 x 6.8 x 8.0 inches, weighs 24.6 oz., and operates within a temperature range of 0 to 50 °C. While it has been marked as obsolete by National Instruments, the SCXI-1102 remains available for purchase and repairs through Apex Waves.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title SCXI-1102 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The National Instruments SCXI-1102 is a 32-channel Voltage Input Module designed for high-accuracy voltage and thermocouple measurements. This module features hardware scanning capability for cold-junction sensors and offers DC input coupling with a 2 Hz bandwidth. Each channel is protected against overvoltage with a tolerance of ±42 V and supports a maximum sampling rate of 333 kS/s. Due to its 2 Hz bandwidth, users must allow approximately 3 seconds after making gain adjustments to achieve accurate readings. The SCXI-1102 can process millivolt and volt signals, as well as current inputs ranging from 0 to 20 mA and 4 to 0 mA. It is also compatible with signals from RTDs when used in conjunction with an SCXI-1581 excitation source. The module is designed to work seamlessly with various terminal blocks including the SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, and TBX-96. For precision in thermocouple applications, the SCXI-1303 is recommended. To operate the SCXI-1102, an SCXI chassis or PXI/SCXI combination chassis, an SCXI-1600 or E/M Series DAQ device, and appropriate cabling, connectors, and sensors are required. Users can develop applications using NI-DAQmx driver software and additional environments such as LabVIEW, LabWindows/CVI, or Measurement Studio. The SCXI-1102 is equipped with a 96-pin male DIN C connector and a 50-pin male ribbon cable rear connector. The module has a physical dimension of 1.2 x 6.8 x 8.0 inches, weighs 24.6 oz., and operates within a temperature range of 0 to 50 °C. While it has been marked as obsolete by National Instruments, the SCXI-1102 remains available for purchase and repairs through Apex Waves.

  • Documentation

    AI Product Assistant

    Ask questions about National Instruments SCXI-1102

    AI Assistant

    Ask questions about National Instruments SCXI-1102

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the Instruments, we offer hundreds of National parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your National replacement parts today.

Contact Us