Description

The National Instruments part number 778572-47 refers to the PXI-2547 PXI RF Multiplexer Switch Module, engineered for precise signal routing in automated testing environments. This module operates over a frequency range from DC to 26.5 GHz, characterized by a maximum switching voltage of 30 V and a maximum current of 0.5 A per channel, with a capacity to handle up to 10 Watts of RF power. Insertion loss is optimized to less than 1.05 dB up to 1 GHz and less than 2.0 dB up to 2.7 GHz. The module maintains a Voltage Standing Wave Ratio (VSWR) below 1.4 at 1 GHz, and below 1.6 at 2.7 GHz, enhancing impedance matching and minimizing signal disruptions. Trigger functionalities are supported through PXI trigger lines <0...7>, with input trigger capabilities featuring a minimum pulse width of 150 ns, and output triggering ranging from 1 µs to 62 µs. The PXI-2547 is engineered for durability, offering a mechanical life rating of 1 × 10^6 cycles and an electrical life of 3 × 10^5 cycles at maximum load. Enclosed in a 3U, single-slot PXI/cPCI form factor, this module measures 21.6 cm x 2.0 cm x 13.0 cm (8.5 in. x 0.8 in. x 5.1 in.) and weighs 255 g. It is designed to withstand operational shocks of up to 30 g peak and random vibrations from 5 Hz to 500 Hz at 0.31 grms. The operating temperature range is from 0 °C to 55 °C, while the storage conditions allow for temperatures from -40 °C to 70 °C. The module supports humidity levels from 10% to 90% non-condensing during operation, and 5% to 95% non-condensing during storage, complying with IEC 60068-2 standards. It is suitable for installation at altitudes up to 2,000 meters and adheres to Pollution Degree 2 standards.
More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title 778572-47 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description
    The National Instruments part number 778572-47 refers to the PXI-2547 PXI RF Multiplexer Switch Module, engineered for precise signal routing in automated testing environments. This module operates over a frequency range from DC to 26.5 GHz, characterized by a maximum switching voltage of 30 V and a maximum current of 0.5 A per channel, with a capacity to handle up to 10 Watts of RF power. Insertion loss is optimized to less than 1.05 dB up to 1 GHz and less than 2.0 dB up to 2.7 GHz. The module maintains a Voltage Standing Wave Ratio (VSWR) below 1.4 at 1 GHz, and below 1.6 at 2.7 GHz, enhancing impedance matching and minimizing signal disruptions. Trigger functionalities are supported through PXI trigger lines <0...7>, with input trigger capabilities featuring a minimum pulse width of 150 ns, and output triggering ranging from 1 µs to 62 µs. The PXI-2547 is engineered for durability, offering a mechanical life rating of 1 × 10^6 cycles and an electrical life of 3 × 10^5 cycles at maximum load. Enclosed in a 3U, single-slot PXI/cPCI form factor, this module measures 21.6 cm x 2.0 cm x 13.0 cm (8.5 in. x 0.8 in. x 5.1 in.) and weighs 255 g. It is designed to withstand operational shocks of up to 30 g peak and random vibrations from 5 Hz to 500 Hz at 0.31 grms. The operating temperature range is from 0 °C to 55 °C, while the storage conditions allow for temperatures from -40 °C to 70 °C. The module supports humidity levels from 10% to 90% non-condensing during operation, and 5% to 95% non-condensing during storage, complying with IEC 60068-2 standards. It is suitable for installation at altitudes up to 2,000 meters and adheres to Pollution Degree 2 standards.
  • Documentation

    AI Product Assistant

    Ask questions about National Instruments 778572-47

    AI Assistant

    Ask questions about National Instruments 778572-47

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the Instruments, we offer hundreds of National parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your National replacement parts today.