Close

Successfully Added

The product is added to your quote.

Honeywell On-Off Primary Burner Control
Honeywell On-Off Primary Burner Control

Honeywell On-Off Primary Burner Control - RM7890A1031/U

SKU: RM7890A1031/U

Estimated delivery: August 2nd - August 4th

Order for next-day shipment.

This product is not available for online purchase.

Use the Request a quote to get the pricing

New and Refurbished
Available
Request a quote

Description

The Honeywell On-Off Primary Burner Control operates with a standard voltage of 120 VAC and a frequency of 50/60 Hz. This control is designed featuring an Intermittent Pilot Type and a 30 Second Fixed Pilot Flame Establishing Period, providing a consistent Intermittent Main Flame Establishing Period.

A myriad of advanced features are incorporated in this Honeywell product. It is skillfully engineered to perform functions such as Automatic Burner Sequencing, Flame Supervision, System Status Indication, along with System and Self Diagnostics, and Troubleshooting for operational efficiency.

To ensure reliable operation, this burner control requires a subbase and an amplifier. For expanded functionality, options for a Modbus interface, a Keyboard Display Module, and a Remote Display Module are also available. The user-friendly design encompasses Five LEDs that provide vital sequence information, and interchangeable plug-in amplifiers for flexible usage.

Both local and remote annunciation of operation and fault information can be achieved, owing to the optional features. Furthermore, the non-volatile memory of this control retains history files and lockout status even after the loss of power. The control also allows users to select relight or lockout on the loss of flame as per their operational needs.

Specifically built as an On-Off Primary Control application, it robustly operates in a wide range of operating conditions, from -40 F to 140 F, maintaining its precision and functionality.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Trusted by 65,000+ customers

    Manufacturers and facilities nationwide rely on us for parts, repairs, and support.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    New and Refurbished RM7890A1031/U 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The Honeywell On-Off Primary Burner Control operates with a standard voltage of 120 VAC and a frequency of 50/60 Hz. This control is designed featuring an Intermittent Pilot Type and a 30 Second Fixed Pilot Flame Establishing Period, providing a consistent Intermittent Main Flame Establishing Period.

    A myriad of advanced features are incorporated in this Honeywell product. It is skillfully engineered to perform functions such as Automatic Burner Sequencing, Flame Supervision, System Status Indication, along with System and Self Diagnostics, and Troubleshooting for operational efficiency.

    To ensure reliable operation, this burner control requires a subbase and an amplifier. For expanded functionality, options for a Modbus interface, a Keyboard Display Module, and a Remote Display Module are also available. The user-friendly design encompasses Five LEDs that provide vital sequence information, and interchangeable plug-in amplifiers for flexible usage.

    Both local and remote annunciation of operation and fault information can be achieved, owing to the optional features. Furthermore, the non-volatile memory of this control retains history files and lockout status even after the loss of power. The control also allows users to select relight or lockout on the loss of flame as per their operational needs.

    Specifically built as an On-Off Primary Control application, it robustly operates in a wide range of operating conditions, from -40 F to 140 F, maintaining its precision and functionality.

  • Documentation

    AI Product Assistant

    Ask questions about Honeywell On-Off Primary Burner Control - RM7890A1031/U

    AI Assistant

    Ask questions about Honeywell On-Off Primary Burner Control - RM7890A1031/U

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the On-Off, we offer hundreds of Honeywell parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your Honeywell replacement parts today.

Contact Us