SINAMICS S120 parts guide
One drives a single 45 A axis. The other drives two axes at 18 A each. Here’s how to tell them apart, size the right one, and swap a failed module without rebuilding your project.
The segments in blue are where these two modules differ.
The 6SL3120-1TE24-5AA3 and the 6SL3120-2TE21-8AA3 are both SINAMICS S120 Motor Modules in Booksize format. A Motor Module is the inverter stage of an S120 drive line-up: it takes DC from the shared DC link, fed by a Line Module, and turns it into variable-frequency AC for a servo or induction motor. It has no brains of its own. A Control Unit such as the CU320-2 runs the closed-loop control and talks to each Motor Module over DRIVE-CLiQ.
The difference is how many motors each one runs. The 6SL3120-1TE24-5AA3 is a Single Motor Module rated 45 A for one axis. The 6SL3120-2TE21-8AA3 is a Double Motor Module with two independent 18 A inverters in one housing, so it runs two axes.
6SL3 marks a SINAMICS product. 120 means a Booksize Motor Module. The digit after the dash is the number of axes: 1 for a Single Motor Module, 2 for a Double. TE places the module in the 600 V DC link class used on 380–480 V lines. The next three digits encode rated current per axis: 24-5 works out to 45 A and 21-8 to 18 A. The suffix, AA3 here, identifies the design version. When you replace a module, match the full order number, or confirm the successor on Siemens Industry Online Support before you order.
| 6SL3120-1TE24-5AA3 | 6SL3120-2TE21-8AA3 | |
|---|---|---|
| Module type | Single Motor Module | Double Motor Module |
| Axes | 1 | 2, controlled independently |
| Rated output current | 45 A | 18 A per axis |
| Rated power | 24 kW | 9.7 kW per axis |
| Peak current | 85 A | 36 A per axis |
| DC link voltage | 510–720 V DC | 510–720 V DC |
| Format and cooling | Booksize, internal air cooling | Booksize, internal air cooling |
| Control interface | DRIVE-CLiQ | DRIVE-CLiQ |
Values are from Siemens SINAMICS S120 Booksize documentation. Confirm current, power and overload ratings against the Siemens datasheet for your application.
Both modules sit on the same DC link and 24 V busbars, so you can mix them in one line-up. The choice comes down to current, panel space and how much downtime one failure can cost you.
Rule of thumb: two axes at 18 A or less that work together, such as X and Y on one machine, are a natural fit for a double module. Anything bigger, or anything you can’t afford to lose alongside another axis, goes on a single.
Size a Motor Module by current, not kilowatts. Work through these before ordering:
For a double module, size each axis on its own. Two 18 A axes don’t combine into one 36 A axis.
These power unit faults are the ones most often traced to a Motor Module. Before you blame the module, check the motor, motor cable and load: many of these start outside the drive.
| Fault | Meaning | Check first |
|---|---|---|
F30001 |
Power unit overcurrent | Motor cable insulation, shorted motor winding, mechanical jam, controller tuning too aggressive |
F30002 |
DC link overvoltage | Regenerative energy during braking, Line Module or braking resistor capacity, deceleration ramps |
F30003 |
DC link undervoltage | Line supply dips, Line Module faults, loose DC link busbar bridges |
F30004 |
Heat sink overtemperature | Fan, blocked airflow, dust, cabinet ambient temperature |
F30005 |
Power unit overload (I²t) | Undersized module for the duty cycle, binding mechanics, brake not releasing |
F30021 |
Ground fault | Motor cable damage, moisture in the motor or connectors |
Fault texts summarised from the SINAMICS S120/S150 List Manual. Use the manual for your firmware version for full causes and remedies.
If a fault follows the module when you swap motor connections to another axis, or comes back immediately with the motor disconnected, the module itself is the likely cause. On a double module, a fault on one axis only may still point to a hardware failure that takes out both axes, so plan the replacement for the whole unit.
Swapping in the same order number is the fastest way back to running. The project, topology and parameters stay the same.
This is not a drop-in swap. Changing between Single and Double Motor Modules changes the DRIVE-CLiQ topology, the number of components and the panel width. You will need to edit the project in Startdrive or STARTER, re-wire DRIVE-CLiQ, confirm busbar and fusing arrangements, and re-commission the affected axes. If your goal is just to get a machine running again, replace like for like and plan any redesign separately.
Many plants do both: install a replacement today to restart production, then repair the failed unit to keep as a shelf spare. Send us your order number and we’ll tell you what we have in stock, new or refurbished.
No. The double module tops out at 18 A per axis, well below the 45 A single, and swapping types changes your drive topology. Replace a failed module with the same order number.
Yes. Single and Double Motor Modules in Booksize format share the same DC link and 24 V busbars and can sit in one line-up, as long as the Line Module and Control Unit are sized for the total.
Sometimes, by deactivating the faulted drive object, but both axes share one housing and power section. Treat a hardware fault on either axis as a reason to replace the whole module.
Usually not. With the same order number on the same DRIVE-CLiQ port, the Control Unit keeps the existing parameters. You may need to accept the new component and save, and Safety Integrated axes may need acceptance steps.
Send us the order number from the rating plate. We’ll confirm stock and pricing, new or IAC Certified Refurbished. Call 1-877-727-8757 or email sales@iac.us.com.