{"product_id":"yaskawa-cimr-au4a0088aaa","title":"Yaskawa CIMR-AU4A0088AAA","description":"\u003cp\u003eSpecifications \n\u003cbr\u003ePrimary brandYaskawa \n\u003cbr\u003eMain functionVariable Speed\/Frequency Drive (VSD\/VFD) \/ Inverter \n\u003cbr\u003eProduct series \/ family nameA1000 series \n\u003cbr\u003eNetwork frequency(output) 0.01-400 Hz \n\u003cbr\u003e(input) 50\/60 Hz \n\u003cbr\u003eFunctionsMulti-purpose Variable Speed\/Frequency Drive (VSD\/VFD) \/ Inverter - USA region \n\u003cbr\u003eDroop Control \n\u003cbr\u003eSpeed\/torque Control Switching \n\u003cbr\u003eFeed Forward Control \n\u003cbr\u003eZero servo function \n\u003cbr\u003eSpeed search \n\u003cbr\u003eOvertorque detection \n\u003cbr\u003eUndertorque detection \n\u003cbr\u003eTorque limit \n\u003cbr\u003e17-step speed \n\u003cbr\u003eAcceleration\/Deceleration time switch \n\u003cbr\u003eS-curve accel\/decel \n\u003cbr\u003e3-wire sequence \n\u003cbr\u003eAuto-tuning \n\u003cbr\u003eDwell \n\u003cbr\u003eCooling fan on\/off switch \n\u003cbr\u003eSlip compensation \n\u003cbr\u003eTorque compensation \n\u003cbr\u003eFrequency jump \n\u003cbr\u003eUpper\/lower limits for frequency reference \n\u003cbr\u003eDC injection braking at start and stop \n\u003cbr\u003eOverexcitation braking \n\u003cbr\u003eHigh slip braking \n\u003cbr\u003ePID control \n\u003cbr\u003eEnergy saving control \n\u003cbr\u003eFault restart \n\u003cbr\u003eApplication presets \n\u003cbr\u003eBackup \n\u003cbr\u003eOnline tuning \n\u003cbr\u003eKEB \n\u003cbr\u003eOverexcitation deceleration \n\u003cbr\u003eInertia (ASR) tuning \n\u003cbr\u003eHigh Frequency Injection \n\u003cbr\u003eSupply voltage (AC)380Vac-480Vac (400Vac \/ 415Vac \/ 440Vac) \n\u003cbr\u003eDisplayLED 5-digit display \n\u003cbr\u003eType of network3-phase input (3P) \n\u003cbr\u003eRated current88A (Normal duty) \n\u003cbr\u003e75A (heavy duty) \n\u003cbr\u003e120% \/ 60s (Normal duty) or 150% \/ 60s (heavy duty) overload current rating \n\u003cbr\u003eRated power (HP)60HP (Normal duty) \n\u003cbr\u003e60HP (heavy duty) \n\u003cbr\u003eProtection functionsMotor overheat \n\u003cbr\u003eOvercurrent \n\u003cbr\u003eOverload \n\u003cbr\u003eOvervoltage \n\u003cbr\u003eUndervoltage \n\u003cbr\u003eMomentary power loss ride-thru \n\u003cbr\u003eOverheat \n\u003cbr\u003eGround fault \n\u003cbr\u003eProtection settings(Overcurrent) output current exceeds 200% of heavy duty rating \n\u003cbr\u003e(Overload) 120% of rated output current; normal duty \n\u003cbr\u003e(Overload) 150% of rated output current; heavy duty \n\u003cbr\u003eCommunication protocolRS-422 \n\u003cbr\u003eRS-485 \n\u003cbr\u003eMounting modeWall mounting \n\u003cbr\u003eDigital inputs1 x digital input (24Vdc; Sink\/Source) (S1 - Forward \/ Stop) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S2 - Reverse \/ Stop) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S3 - External fault) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S4 - Fault reset) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S5 - Multi-step speed 1) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S6 - Multi-step speed 2) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S7 - Jog speed) \n\u003cbr\u003e1 x digital input (24Vdc; Sink\/Source) (S8 - External Baseblock) \n\u003cbr\u003e1 x digital input (Pulse train input) \n\u003cbr\u003eDigital outputs1 x digital output (SPDT Single Pole Double Throw contact type) (MA-MB-MC; MC-MB closed means fault) \n\u003cbr\u003e1 x digital output (NO Normally Open contact type \/ Multi-function contact output) (M1-M2) \n\u003cbr\u003e1 x digital output (NO Normally Open contact type \/ Multi-function contact output (Zero speed) contact) (M3-M4) \n\u003cbr\u003e1 x digital output (NO Normally Open contact type \/ Multi-function (Speed agree 1) contact output) (M5-M6) \n\u003cbr\u003e1 x digital output (multi-function pulse train) (MP) \n\u003cbr\u003eAnalog inputs1 x analog input (-10...+10Vdc \/ 20kΩ) (Analog Input 1 - Frequency reference bias) \n\u003cbr\u003e1 x analog input (0-20mA \/ 4-20mA \/ -10...+10Vdc \/ 250Ω) (Analog Input 2 - Frequency reference bias) \n\u003cbr\u003e1 x analog input (-10...+10Vdc \/ PTC input) (Analog input 3 - Aux. frequency reference or motor temperature) \n\u003cbr\u003eAnalog outputs1 x analog output (4-20mA \/ -10...+10Vdc) (FM - to output frequency meter) \n\u003cbr\u003e1 x analog output (4-20mA \/ -10...+10Vdc) (AM - to output current meter) \n\u003cbr\u003eDegree of protectionIP00 \n\u003cbr\u003eNet Height (mm)501.5 mm \n\u003cbr\u003eNet Width (mm)329 mm \n\u003cbr\u003eNet Depth (mm)256.75 mm \n\u003cbr\u003eAmbient air temperature for storage-20...+60 °C \n\u003cbr\u003eTechnology used in componentForced ventilation (Fan-cooling) \n\u003cbr\u003eStandard heatsink fins \n\u003cbr\u003eIntegrated DC choke \n\u003cbr\u003eRated apparent power (S)67kVA (Normal duty) \n\u003cbr\u003e57kVA (heavy duty) \n\u003cbr\u003eApplication typeHVAC \n\u003cbr\u003eFans \n\u003cbr\u003ePumps \n\u003cbr\u003eCompressors \n\u003cbr\u003eConveyors \n\u003cbr\u003eMachine Tools \n\u003cbr\u003eExtruders \n\u003cbr\u003ePunching Presses \n\u003cbr\u003eWinders \n\u003cbr\u003eOrder code \/ Manufacturer SKUCIMRAU4A0088AAA \n\u003cbr\u003eManufacturer product statusCommercialized \n\u003cbr\u003eCompliant with standard(s)UL 508C \n\u003cbr\u003eCSA C22.2 \n\u003cbr\u003eIEC 61508 \n\u003cbr\u003eIEC 61800-5-1\u003c\/p\u003e","brand":"Yaskawa","offers":[{"title":"New","offer_id":46227356319980,"sku":"CIMR-AU4A0088AAA","price":3910.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/CIMR-AU4A0088AAA.jpg?v=1763016060","url":"https:\/\/www.industrialautomationco.com\/products\/yaskawa-cimr-au4a0088aaa","provider":"Industrial Automation Co.","version":"1.0","type":"link"}