{"product_id":"control-techniques-sp2404","title":"Control Techniques SP2404","description":"\u003ch2\u003eControl Techniques SP2404\u003c\/h2\u003e\n\u003cp\u003eThe Control Techniques SP2404 is an efficient servo drive that offers high performance and reliability. This drive is a member of the Unidrive SP series, which is known for its flexibility, scalability, and comprehensive feature set.\u003c\/p\u003e\n\u003cp\u003eIt is engineered to provide precise control of servo motors, enhancing the efficiency and productivity of automated systems. The SP2404 is ideal for demanding environments, offering robust performance under various operational conditions.\u003c\/p\u003e\n\u003ch2\u003eTechnical Description:\u003c\/h2\u003e\n\u003cp\u003eThe SP2404 model can handle a maximum continuous input current of 27.6 A for both single-phase and three-phase configurations. To ensure safe operation, it requires appropriate fuses rated at 32 A for IEC gG and 30 A for UL standards.\u003c\/p\u003e\n\u003cp\u003eThe device supports cable sizes of 6 mm² for both input and output as per EN60204 standards, and 8 AWG for input and 8 AWG for output according to UL508C standards.\u003c\/p\u003e\n\u003cp\u003eRegarding output performance, the SP2404 is designed for both normal and heavy-duty operations. Under normal duty, it can handle a maximum continuous output current of 29 A, supporting motor power of up to 15 kW at 480V and 20 kW at 230 V. For heavy-duty applications, the drive manages a continuous output current of 29 A, with motor power capabilities of 15 kW at 480 V and 10 kW at 230 V.\u003c\/p\u003e\n\u003ch2\u003eKey Environmental Specifications:\u003c\/h2\u003e\n\u003cp\u003eThe SP2404 integrates several key features to enhance its functionality and usability. It operates within a wide temperature range of 32 °F to 122 °F, with a minimum temperature at power-up of -10 °C (14 °F).\u003c\/p\u003e\n\u003cp\u003eThe drive employs forced convection cooling to maintain optimal performance and reliability. It can also operate effectively in high humidity environments, with a humidity tolerance of 95 % non-condensing at 40 °C (104 °F). The drive's storage capabilities are also notable. The storage temperature range is between - 40 °F to 122 °F, ensuring the drive remains functional and protected during long periods of inactivity.\u003c\/p\u003e\n\u003ch2\u003eLine Filters:\u003c\/h2\u003e\n\u003cp\u003eAnother important consideration is the use of line reactors. These reduce the risk of damage to the drive from severe disturbances on the supply network, such as power factor correction equipment connected close to the drive, or large DC drives with ineffective line reactors.\u003c\/p\u003e\n\u003cp\u003eDirect-on-line started motors connected to the supply can cause excessive peak currents, potentially leading to nuisance tripping or drive failure. Implementing line reactors helps mitigate these risks, ensuring stable and reliable operation.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e\n\u003ch3\u003eWhat is the maximum continuous output current for the SP2404 in normal duty?\u003c\/h3\u003e\n\u003cp\u003eThe SP2404 can handle a maximum continuous output current of 29 A in normal duty. It supports motor power up to 15 kW at 220 V and 20 kW at 230 V.\u003c\/p\u003e\n\u003ch3\u003eWhat are the fuse ratings required for the SP2404 model?\u003c\/h3\u003e\n\u003cp\u003eThe SP2404 requires 32 A fuses for IEC gG standards. For UL standards, it requires 30 A fuses.\u003c\/p\u003e\n\u003ch3\u003eWhat cable sizes does the SP2404 support?\u003c\/h3\u003e\n\u003cp\u003eThe SP2404 supports 6 mm² cables for both input and output per EN60204 standards. For UL508C standards, it supports 8 AWG cables for both input and output.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications Table\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUnidrive SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Input Current\u003c\/td\u003e\n\u003ctd\u003e27.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Fuses\u003c\/td\u003e\n\u003ctd\u003e32 A (IEC gG), 30 A (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Cable Sizes\u003c\/td\u003e\n\u003ctd\u003e6 mm² (EN60204), 8 AWG (UL508C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Output Current (Normal Duty)\u003c\/td\u003e\n\u003ctd\u003e29 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power (Normal Duty)\u003c\/td\u003e\n\u003ctd\u003e15 kW (220 V), 20 kW (230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e32 °F to 122 °F (0 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eForced Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing at 104 °F (40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Control Techniques","offers":[{"title":"New Surplus","offer_id":47607912497388,"sku":"SP2404-NS","price":4990.0,"currency_code":"USD","in_stock":true},{"title":"IAC Certified Refurbished","offer_id":44007464894700,"sku":"SP2404-R","price":3190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/control-techniques-sp2404-new-surplus-842.jpg?v=1780934535","url":"https:\/\/www.industrialautomationco.com\/products\/control-techniques-sp2404","provider":"Industrial Automation Co.","version":"1.0","type":"link"}