{"title":"Penn-Union Compression Tools \u0026 Dies","description":"\u003cp\u003ePenn-Union compression tools, dies, hydraulic pumps, cable cutters and tool accessories for installing Penn-Union compression connectors. Match the tool and die to the connector you are installing.\u003c\/p\u003e\u003cp\u003eIndustrial Automation Co. is an authorized Penn-Union distributor: every part is new and carries Penn-Union's manufacturer warranty.\u003c\/p\u003e","products":[{"product_id":"penn-union-bc-07","title":"Penn-Union BC-07","description":"\u003cp\u003eThe Penn-Union BC-07 is an 18-volt lithium-ion battery charger for Penn-Union LI-18-A and LI-18-B batteries. An LED display shows charging status, providing a visible reference while the battery is charging. Battery protection circuitry is designed to prevent overcharging. The two identified battery models establish the charger compatibility; the 18-volt label should not be treated as a universal battery interface. The charger supports the rechargeable battery system used with the applicable Penn-Union powered tools, giving the battery a dedicated charging component between working cycles. Use the battery and charger combination specified for the selected tool system. Compatibility depends on the identified battery interface and tool models, so matching voltage alone is insufficient when choosing a battery or charger. For an existing tool kit, compare the complete model number before replacing a battery or adding a charging component. A rechargeable tool setup includes the tool, its battery and the applicable charger. Keeping those components identified together supports planning for repeated work, replacement batteries, and charging between operations. Battery capacity and charging time describe different characteristics, and neither should be read as a guaranteed number of cuts or crimps for every application. This accessory supplies its stated role within that tool system. Review the tool's instructions for battery installation, charging and use, and keep the accessory model with the tool information when organizing the kit. That helps maintain a clear record of the compatible components used at each working location. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664082469100,"sku":"BC-07","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/BC-07.png?v=1791309978"},{"product_id":"penn-union-bct-750","title":"Penn-Union BCT-750","description":"\u003cp\u003eThe Penn-Union BCT-750 is a battery-operated ratchet cable cutter for electrical connection work. Its stated application is hard-drawn cable up to 750 kcmil. The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. Operation uses an 18-volt lithium-ion battery, bringing the powered operation to the work position. Hardened steel blades provide the working cutting surfaces. The supplied carrying case provides a place to keep the tool between jobs. The listed package includes a battery charger. The lightweight hook-head design supports positioning the cutter around the cable at the cutting point. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664082534636,"sku":"BCT-750","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/BCT-750.png?v=1791309981"},{"product_id":"penn-union-bcta-1000","title":"Penn-Union BCTA-1000","description":"\u003cp\u003eThe Penn-Union BCTA-1000 is a battery-operated hydraulic cable cutter for electrical connection work. Its stated application is conductors up to 1250 kcmil. Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. The flip-top head provides access for positioning and removing the cable or connector. The head swivels through 180 degrees, helping orient the tool to the connection or cutting position. Operation uses an 18-volt lithium-ion battery, bringing the powered operation to the work position. The supplied carrying case provides a place to keep the tool between jobs. The listed package includes a battery charger. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664082600172,"sku":"BCTA-1000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/BCTA-1000.png?v=1791309983"},{"product_id":"penn-union-c-18","title":"Penn-Union C-18","description":"\u003cp\u003eThe Penn-Union C-18 is a complete quick coupler with 3\/8-inch male NPT threads at both ends. The complete-coupler description distinguishes the assembly from separately ordered coupling halves. The male threaded connections establish how the coupler attaches at each end, while the quick-coupling interface provides the connecting function within the assembled line. Matching the threaded connections and the mating coupling arrangement are separate parts of selecting the correct component. At the threaded end, the component attaches to a fitting on the hose or equipment. At the coupling interface, it joins the corresponding coupling component. These are separate connections within the assembled line, and each must match the component it meets. A complete coupler provides the mating coupling arrangement together, while an individual half forms one side of that arrangement. The coupling connection is useful where the line is assembled from components that need a defined joining point. Once connected, the surrounding hose and equipment still determine the route and working arrangement of the line. Allow room around the coupling interface for engagement and disengagement under the equipment's specified procedure, and keep the threaded attachment aligned with its mating fitting. For this component, the 3\/8-inch NPT specification identifies the threaded interface; the coupling designation identifies the separate joining interface. Both belong in the connection specification. Match the full coupling arrangement, thread configuration and applicable operating limits before assembling the line, using the manufacturer's instructions for the connected equipment. This makes the coupling part of a defined equipment connection rather than an unspecified fitting chosen only by its thread size. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664083681516,"sku":"C-18","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/C-18.png?v=1791309985"},{"product_id":"penn-union-c-18-f","title":"Penn-Union C-18-F","description":"\u003cp\u003eThe Penn-Union C-18-F is a female coupling connector supplied as a female coupling half with a 3\/8-inch male NPT screw-type connection. The female designation describes the coupling interface, while the male NPT designation describes its threaded attachment. Keeping those two descriptions separate helps identify the component correctly when assembling or replacing a coupling. This model is the individual female half, so the mating coupling component must be selected as part of the complete arrangement. At the threaded end, the component attaches to a fitting on the hose or equipment. At the coupling interface, it joins the corresponding coupling component. These are separate connections within the assembled line, and each must match the component it meets. A complete coupler provides the mating coupling arrangement together, while an individual half forms one side of that arrangement. The coupling connection is useful where the line is assembled from components that need a defined joining point. Once connected, the surrounding hose and equipment still determine the route and working arrangement of the line. Allow room around the coupling interface for engagement and disengagement under the equipment's specified procedure, and keep the threaded attachment aligned with its mating fitting. For this component, the 3\/8-inch NPT specification identifies the threaded interface; the coupling designation identifies the separate joining interface. Both belong in the connection specification. Match the full coupling arrangement, thread configuration and applicable operating limits before assembling the line, using the manufacturer's instructions for the connected equipment. This makes the coupling part of a defined equipment connection rather than an unspecified fitting chosen only by its thread size.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664083779820,"sku":"C-18-F","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/C-18-F.png?v=1791309987"},{"product_id":"penn-union-c-18-m","title":"Penn-Union C-18-M","description":"\u003cp\u003eThe Penn-Union C-18-M is a male coupling connector supplied as a male coupling half with 3\/8-inch NPT threads. The male coupling designation identifies its mating interface. The thread specification identifies the attachment size and thread system on the component, giving a separate reference for the connection to the surrounding equipment. This model is an individual coupling half, so the mating female component remains part of selecting the complete coupling arrangement. At the threaded end, the component attaches to a fitting on the hose or equipment. At the coupling interface, it joins the corresponding coupling component. These are separate connections within the assembled line, and each must match the component it meets. A complete coupler provides the mating coupling arrangement together, while an individual half forms one side of that arrangement. The coupling connection is useful where the line is assembled from components that need a defined joining point. Once connected, the surrounding hose and equipment still determine the route and working arrangement of the line. Allow room around the coupling interface for engagement and disengagement under the equipment's specified procedure, and keep the threaded attachment aligned with its mating fitting. For this component, the 3\/8-inch NPT specification identifies the threaded interface; the coupling designation identifies the separate joining interface. Both belong in the connection specification. Match the full coupling arrangement, thread configuration and applicable operating limits before assembling the line, using the manufacturer's instructions for the connected equipment. This makes the coupling part of a defined equipment connection rather than an unspecified fitting chosen only by its thread size. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664084566252,"sku":"C-18-M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/C-18-M.png?v=1791309990"},{"product_id":"penn-union-c-20","title":"Penn-Union C-20","description":"\u003cp\u003eThe Penn-Union C-20 is a complete quick coupler with 3\/8-inch female NPT threads at both ends. The complete-coupler description distinguishes this assembly from individual coupling halves. Its female threaded connections establish the attachment arrangement at each end. The quick-coupling interface and the threaded ends perform different roles: the coupling joins the mating components, while the threaded connections attach the assembly to the surrounding line or equipment. At the threaded end, the component attaches to a fitting on the hose or equipment. At the coupling interface, it joins the corresponding coupling component. These are separate connections within the assembled line, and each must match the component it meets. A complete coupler provides the mating coupling arrangement together, while an individual half forms one side of that arrangement. The coupling connection is useful where the line is assembled from components that need a defined joining point. Once connected, the surrounding hose and equipment still determine the route and working arrangement of the line. Allow room around the coupling interface for engagement and disengagement under the equipment's specified procedure, and keep the threaded attachment aligned with its mating fitting. For this component, the 3\/8-inch NPT specification identifies the threaded interface; the coupling designation identifies the separate joining interface. Both belong in the connection specification. Match the full coupling arrangement, thread configuration and applicable operating limits before assembling the line, using the manufacturer's instructions for the connected equipment. This makes the coupling part of a defined equipment connection rather than an unspecified fitting chosen only by its thread size. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664085188844,"sku":"C-20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/C-20.png?v=1791309994"},{"product_id":"penn-union-c-20-f","title":"Penn-Union C-20-F","description":"\u003cp\u003eThe Penn-Union C-20-F is a female coupling connector with a 3\/8-inch female NPT threaded attachment and a push\/pull quick-connect interface. The female coupling half forms one side of the complete connection. Push\/pull operation describes how the quick-connect interface is engaged, while the NPT threads describe its attachment to the surrounding line or equipment. Identifying both interfaces helps match the connector to the planned assembly without confusing coupling gender with thread gender. At the threaded end, the component attaches to a fitting on the hose or equipment. At the coupling interface, it joins the corresponding coupling component. These are separate connections within the assembled line, and each must match the component it meets. A complete coupler provides the mating coupling arrangement together, while an individual half forms one side of that arrangement. The coupling connection is useful where the line is assembled from components that need a defined joining point. Once connected, the surrounding hose and equipment still determine the route and working arrangement of the line. Allow room around the coupling interface for engagement and disengagement under the equipment's specified procedure, and keep the threaded attachment aligned with its mating fitting. For this component, the 3\/8-inch NPT specification identifies the threaded interface; the coupling designation identifies the separate joining interface. Both belong in the connection specification. Match the full coupling arrangement, thread configuration and applicable operating limits before assembling the line, using the manufacturer's instructions for the connected equipment. This makes the coupling part of a defined equipment connection rather than an unspecified fitting chosen only by its thread size.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664085811436,"sku":"C-20-F","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/C-20-F.png?v=1791309996"},{"product_id":"penn-union-c-20-m","title":"Penn-Union C-20-M","description":"\u003cp\u003eThe Penn-Union C-20-M is a male coupling connector supplied as a male coupling half with a 3\/8-inch female NPT threaded attachment. The male designation refers to the coupling interface, while the female designation refers to the NPT threads. Those two interfaces belong to different parts of the component. This distinction is useful when replacing a coupling half or arranging the connection between a mating coupler and the surrounding equipment. At the threaded end, the component attaches to a fitting on the hose or equipment. At the coupling interface, it joins the corresponding coupling component. These are separate connections within the assembled line, and each must match the component it meets. A complete coupler provides the mating coupling arrangement together, while an individual half forms one side of that arrangement. The coupling connection is useful where the line is assembled from components that need a defined joining point. Once connected, the surrounding hose and equipment still determine the route and working arrangement of the line. Allow room around the coupling interface for engagement and disengagement under the equipment's specified procedure, and keep the threaded attachment aligned with its mating fitting. For this component, the 3\/8-inch NPT specification identifies the threaded interface; the coupling designation identifies the separate joining interface. Both belong in the connection specification. Match the full coupling arrangement, thread configuration and applicable operating limits before assembling the line, using the manufacturer's instructions for the connected equipment. This makes the coupling part of a defined equipment connection rather than an unspecified fitting chosen only by its thread size. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664085909740,"sku":"C-20-M","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/C-20-M.png?v=1791309999"},{"product_id":"penn-union-ct-1000","title":"Penn-Union CT-1000","description":"\u003cp\u003eThe Penn-Union CT-1000 is a hand-operated ratchet cable cutter for electrical connection work. Its stated application is 1000 kcmil (max.). The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. Non-slip rubber grips support hand placement on the steel handles. The cutting blades can be opened during the cycle, allowing the operator to reposition before completing a cut. Two-handed operation provides additional leverage for the cutting stroke. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position. Keep the complete tool number with the cable-preparation information for later jobs. This helps identify the same cutting setup when repeating the work and provides a clear reference when reviewing the applicable operating instructions.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664086401260,"sku":"CT-1000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/CT-1000.png?v=1791310002"},{"product_id":"penn-union-ct-2-0","title":"Penn-Union CT-2\/0","description":"\u003cp\u003eThe Penn-Union CT-2\/0 is a hand-operated cable cutter for electrical connection work. Its stated application is 2\/0 AWG (max.). Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. Forged steel construction provides the working structure of the tool. Insulated handles provide the handle construction identified for this model. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position. Keep the complete tool number with the cable-preparation information for later jobs. This helps identify the same cutting setup when repeating the work and provides a clear reference when reviewing the applicable operating instructions.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664086499564,"sku":"CT-2\/0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/CT-2_0.png?v=1791310004"},{"product_id":"penn-union-ct-250","title":"Penn-Union CT-250","description":"\u003cp\u003eThe Penn-Union CT-250 is a hand-operated cable cutter for electrical connection work. Its stated application is 250 kcmil (max.). Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. Heat-treated steel blades provide the cutting surfaces for the cable-cutting operation. Non-slip rubber grips support hand placement on the steel handles. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position. Keep the complete tool number with the cable-preparation information for later jobs. This helps identify the same cutting setup when repeating the work and provides a clear reference when reviewing the applicable operating instructions.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664086630636,"sku":"CT-250","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/CT-250.png?v=1791310006"},{"product_id":"penn-union-ct-750","title":"Penn-Union CT-750","description":"\u003cp\u003eThe Penn-Union CT-750 is a hand-operated ratchet cable cutter for electrical connection work. Its stated application is 750 kcmil (max.). The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. Heat-treated steel blades provide the cutting surfaces for the cable-cutting operation. The cutting blades can be opened during the cycle, allowing the operator to reposition before completing a cut. The hand-operated mechanism is designed for one-handed operation. A black oxide finish protects the specified tool surfaces against corrosion. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664087089388,"sku":"CT-750","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/CT-750.png?v=1791310009"},{"product_id":"penn-union-cta-750","title":"Penn-Union CTA-750","description":"\u003cp\u003eThe Penn-Union CTA-750 is a hand-operated ratchet cable cutter for electrical connection work. Its stated application is 750 kcmil (max.) Two cutting actions – fast scissor, quickly cut small cable in scissor mode, cutter converts automatically to ratchet mode for larger cables 1-year limited warranty (excluding blades). The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. The cutter offers scissor action for small cable and automatically changes to ratchet operation for larger cable. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664087187692,"sku":"CTA-750","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/CTA-750.png?v=1791310011"},{"product_id":"penn-union-dct-750","title":"Penn-Union DCT-750","description":"\u003cp\u003eThe Penn-Union DCT-750 is a drill-operated cable cutter for electrical connection work. Its stated application is 750 kcmil (max.). Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. The drill-driven cutter attaches to a drill that accepts a 3\/8-inch drive shaft; the drill is supplied separately. Contour-machined blades are intended to reduce cable distortion during cutting. Replaceable blades allow the cutting surfaces to be changed as part of tool maintenance. A metal housing encloses the drive components, with durable gears transmitting the drill-driven cutting action. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664087974124,"sku":"DCT-750","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/DCT-750.png?v=1791310014"},{"product_id":"penn-union-h-10","title":"Penn-Union H-10","description":"\u003cp\u003eThe Penn-Union H-10 is a hydraulic hose measuring 10 feet long, with a maximum pressure of 10,000 psi and 3\/8-inch male NPT threaded ends. The hose provides the flexible line between hydraulic components, while its threaded ends establish the connection interface. Its length determines how the components can be positioned relative to one another, and its maximum pressure is the stated limit for this hose. The hose rating should be considered alongside the ratings of the pump, couplers and driven tool. When planning the hydraulic arrangement, compare the component's stated pressure limit and connection details with the remaining equipment. A matching thread is one part of the interface; the pump, hose, couplers and driven tool also need to form a suitable complete system. Review the applicable equipment instructions for the connection and operating procedure. For replacement or service work, the full part number helps distinguish the component from another accessory with a similar appearance. Record the pressure specification, interface and stated function together so the replacement can be matched to the actual arrangement. Position the assembled components with attention to the working space and the route between the pump and tool. The flexible line allows the pump and driven tool to occupy separate positions within the available working area. Its stated length provides a fixed reach for that arrangement, with the threaded ends establishing the attachment points. Plan the route to accommodate the required tool position and the equipment's hose-handling instructions. The hose carries the hydraulic fluid; the connected tool determines the operation performed at the other end. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664088105196,"sku":"H-10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/H-6.png?v=1791310016"},{"product_id":"penn-union-h-6","title":"Penn-Union H-6","description":"\u003cp\u003eThe Penn-Union H-6 is a hydraulic hose measuring 6 feet long, with a maximum pressure of 10,000 psi and 3\/8-inch male NPT threaded ends. The hose provides the flexible line between hydraulic components, while its threaded ends establish the connection interface. Its length determines how the components can be positioned relative to one another, and its maximum pressure is the stated limit for this hose. The hose rating should be considered alongside the ratings of the pump, couplers and driven tool. When planning the hydraulic arrangement, compare the component's stated pressure limit and connection details with the remaining equipment. A matching thread is one part of the interface; the pump, hose, couplers and driven tool also need to form a suitable complete system. Review the applicable equipment instructions for the connection and operating procedure. For replacement or service work, the full part number helps distinguish the component from another accessory with a similar appearance. Record the pressure specification, interface and stated function together so the replacement can be matched to the actual arrangement. Position the assembled components with attention to the working space and the route between the pump and tool. The flexible line allows the pump and driven tool to occupy separate positions within the available working area. Its stated length provides a fixed reach for that arrangement, with the threaded ends establishing the attachment points. Plan the route to accommodate the required tool position and the equipment's hose-handling instructions. The hose carries the hydraulic fluid; the connected tool determines the operation performed at the other end. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664089153772,"sku":"H-6","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/H-6_ec492c7f-4965-4788-9cb0-28693fcfa243.png?v=1791310018"},{"product_id":"penn-union-hct-1000","title":"Penn-Union HCT-1000","description":"\u003cp\u003eThe Penn-Union HCT-1000 is a hand-operated hydraulic cable cutter for electrical connection work. Its stated application is 1000 kcmil (max.). Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. An automatic two-speed pump advances the working mechanism rapidly before the compression or cutting stage. The flip-top head provides access for positioning and removing the cable or connector. The head swivels through 180 degrees, helping orient the tool to the connection or cutting position. Heat-treated steel blades provide the cutting surfaces for the cable-cutting operation. The cutting applications include copper, aluminum and ACSR conductors, soft steel bar up to 5\/8 inch, and rebar up to 1\/2 inch. A nylon bag with a carrying strap is included for handling between work locations. The cutter performs the cable-preparation step before a new connection is made. Compare its stated size capacity with the actual cable, and confirm that the cable construction and material are included in the manufacturer's cutting applications. Nominal conductor size describes the conductive area, while the actual cable construction also affects the cutting task. Reviewing both keeps the selected cutter aligned with the work being performed. Position the cable and cutter according to the applicable instructions, with room for the working head and the handle or drive movement. The cutting point should also allow access for removal after the stroke. This is useful when preparing a cable within an existing assembly, where the surrounding conductors and enclosure can affect the available approach to the cut. For a replacement cutter or an addition to an installation kit, compare the operating format as well as the stated capacity. Hand-operated, ratchet, hydraulic and drill-driven models apply the cutting stroke differently. The selected model provides the operating method described for this part, while the installation task establishes which method suits the actual work position.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664089481452,"sku":"HCT-1000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HCT-1000.png?v=1791310021"},{"product_id":"penn-union-hdt-1000","title":"Penn-Union HDT-1000","description":"\u003cp\u003eThe Penn-Union HDT-1000 is a hand-operated dieless hydraulic compression tool for electrical connection work. The stated conductor range is 1\/0 AWG - 900 kcmil. Match that size range with the connector or terminal type specified for this model when planning the installation. The dieless format creates the compression with the tool's own working profile, avoiding separate die inserts for the stated installation system. An automatic two-speed pump advances the working mechanism rapidly before the compression or cutting stage. An audible pressure pop-off valve signals completion of the hydraulic crimp cycle. A hinged head opens to help position the connector or remove the completed connection. The head swivels through 180 degrees, helping orient the tool to the connection or cutting position. Seven indent profiles are formed in each crimp, a design Penn-Union describes as reducing the number of crimps required per connector. The supplied carrying case provides a place to keep the tool between jobs. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664089579756,"sku":"HDT-1000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HDT-1000.png?v=1791310023"},{"product_id":"penn-union-hdt-1000b","title":"Penn-Union HDT-1000B","description":"\u003cp\u003eThe Penn-Union HDT-1000B is a battery-operated dieless hydraulic compression tool for electrical connection work. The stated conductor range is 1\/0 AWG - 900 kcmil. Match that size range with the connector or terminal type specified for this model when planning the installation. The dieless format creates the compression with the tool's own working profile, avoiding separate die inserts for the stated installation system. An audible pressure pop-off valve signals completion of the hydraulic crimp cycle. A hinged head opens to help position the connector or remove the completed connection. The head swivels through 180 degrees, helping orient the tool to the connection or cutting position. Seven indent profiles are formed in each crimp, a design Penn-Union describes as reducing the number of crimps required per connector. Operation uses an 18-volt lithium-ion battery, bringing the powered operation to the work position. An integral LED work light helps illuminate the area around the tool head. The supplied carrying case provides a place to keep the tool between jobs. The listed package includes a battery charger. The specified output force is 12 Ton. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664097640684,"sku":"HDT-1000B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HDT-1000B.png?v=1791310026"},{"product_id":"penn-union-hp-3000","title":"Penn-Union HP-3000","description":"\u003cp\u003eThe Penn-Union HP-3000 is a 10,000-psi electric hydraulic pump for supplying hydraulic pressure to a compatible tool setup. The pump is the pressure-producing component of the arrangement, connected to the driven tool through the hydraulic hose and coupling system. Penn-Union identifies use with its remote-operated tools. A pendant control with a 6-foot operating cord allows the user to advance and retract the tool. The pump starts with low-pressure, high-volume advance and automatically changes to low-volume, high-pressure operation for the working stage. A red LED identifies the on position. A cast-aluminum reservoir holds the hydraulic oil, with an inspection window for checking its level and integral handles for carrying the pump. A 6-foot hydraulic hose with a quick-connect coupler is included, supplying the listed connection accessory for the pump setup. The pressure specification is a pump characteristic; the output force and working capacity of the connected tool depend on that tool and the complete approved arrangement. Select the pump together with the remote tool, hose and couplers required for the connection task. Compare pressure requirements and mating interfaces before assembling the components, and use the applicable instructions for the chosen tool and pump combination. That keeps the pressure source aligned with the equipment it will operate. In a working layout, allow space for the pump controls and a suitable route for the hose to the tool head. The operator needs access to the advance and release functions, while the tool head needs room for the connector or cable being worked. Considering both locations helps establish how the complete hydraulic arrangement will be used within the available work area.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664100458732,"sku":"HP-3000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HP-3000.png?v=1791310029"},{"product_id":"penn-union-htc-1210","title":"Penn-Union HTC-1210","description":"\u003cp\u003eThe Penn-Union HTC-1210 is a hand-operated ratchet compression tool for electrical connection work. The stated conductor range is 12 - 10 AWG. Match that size range with the connector or terminal type specified for this model when planning the installation. This model is specified for insulated terminals. The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. A locking ratchet controls completion of the working stroke, helping the operator carry the crimp cycle through to its intended end. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664105439468,"sku":"HTC-1210","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HTC-1210.png?v=1791310032"},{"product_id":"penn-union-htc-1808","title":"Penn-Union HTC-1808","description":"\u003cp\u003eThe Penn-Union HTC-1808 is a hand-operated ratchet compression tool for electrical connection work. The stated conductor range is 18 - 10 AWG \u0026amp; 14 - 8 AWG. Match that size range with the connector or terminal type specified for this model when planning the installation. This model is specified for non-insulated terminals. The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. A locking ratchet controls completion of the working stroke, helping the operator carry the crimp cycle through to its intended end. Marked die grooves identify the conductor range at the tool, providing a reference when choosing the crimp position. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664109535468,"sku":"HTC-1808","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HTC-1808.png?v=1791310034"},{"product_id":"penn-union-htc-2214","title":"Penn-Union HTC-2214","description":"\u003cp\u003eThe Penn-Union HTC-2214 is a hand-operated ratchet compression tool for electrical connection work. The stated conductor range is 22 - 14 AWG. Match that size range with the connector or terminal type specified for this model when planning the installation. This model is specified for insulated terminals. The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. A locking ratchet controls completion of the working stroke, helping the operator carry the crimp cycle through to its intended end. Color-coded crimp grooves help identify the working positions for terminal selection. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664110977260,"sku":"HTC-2214","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HTC-2214.png?v=1791310037"},{"product_id":"penn-union-htc-228","title":"Penn-Union HTC-228","description":"\u003cp\u003eThe Penn-Union HTC-228 is a hand-operated ratchet compression tool for electrical connection work. The stated conductor range is 22 - 8 AWG. Match that size range with the connector or terminal type specified for this model when planning the installation. The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. A locking ratchet controls completion of the working stroke, helping the operator carry the crimp cycle through to its intended end. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664112713964,"sku":"HTC-228","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HTC-228.png?v=1791310039"},{"product_id":"penn-union-htc-3200","title":"Penn-Union HTC-3200","description":"\u003cp\u003eThe Penn-Union HTC-3200 is a hand-operated ratchet compression tool for electrical connection work. The stated conductor range is 22 - 10 AWG. Match that size range with the connector or terminal type specified for this model when planning the installation. This model is specified for insulated terminals. The ratchet format advances the working stroke in stages, giving the operator a controlled sequence for the cable or terminal operation. A locking ratchet controls completion of the working stroke, helping the operator carry the crimp cycle through to its intended end. Color-coded crimp grooves help identify the working positions for terminal selection. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664114712812,"sku":"HTC-3200","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HTC-3200.png?v=1791310042"},{"product_id":"penn-union-hts-1","title":"Penn-Union HTS-1","description":"\u003cp\u003eThe Penn-Union HTS-1 is a hand-operated compression tool for electrical connection work. The stated conductor range is 22 - 10 AWG. Match that size range with the connector or terminal type specified for this model when planning the installation. Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. Color-coded crimp grooves help identify the working positions for terminal selection. The integrated stripping function supports wire preparation before termination. The integrated bolt cutter adds a separate preparation function within the same hand tool. An anvil-type wire cutter provides the wire-cutting function. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664114778348,"sku":"HTS-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/HTS-1.png?v=1791310044"},{"product_id":"penn-union-li-18-a","title":"Penn-Union LI-18-A","description":"\u003cp\u003eThe Penn-Union LI-18-A is an 18-volt DC lithium-ion battery with a 3 Ah capacity and a stated charging time of 60 minutes. It is identified for Penn-Union TPU-6B, TPU-6FTB, TPU-42B, BCT-750, BCTA-1000 and HDT-1000B tools. The voltage describes the battery output, while the amp-hour capacity distinguishes this model within the compatible battery range. The stated charging time is a charging specification, rather than an estimate of tool operating time. Actual work per charge depends on the tool and its operating task. Use the battery and charger combination specified for the selected tool system. Compatibility depends on the identified battery interface and tool models, so matching voltage alone is insufficient when choosing a battery or charger. For an existing tool kit, compare the complete model number before replacing a battery or adding a charging component. A rechargeable tool setup includes the tool, its battery and the applicable charger. Keeping those components identified together supports planning for repeated work, replacement batteries, and charging between operations. Battery capacity and charging time describe different characteristics, and neither should be read as a guaranteed number of cuts or crimps for every application. This accessory supplies its stated role within that tool system. Review the tool's instructions for battery installation, charging and use, and keep the accessory model with the tool information when organizing the kit. That helps maintain a clear record of the compatible components used at each working location. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664114843884,"sku":"LI-18-A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/LI-18-A.png?v=1791310046"},{"product_id":"penn-union-li-18-b","title":"Penn-Union LI-18-B","description":"\u003cp\u003eThe Penn-Union LI-18-B is an 18-volt DC lithium-ion battery with a 1.5 Ah capacity and a stated charging time of 30 minutes. It is identified for Penn-Union TPU-6B, TPU-6FTB, TPU-42B, BCT-750, BCTA-1000 and HDT-1000B tools. The voltage describes the battery output, while the amp-hour capacity distinguishes this model within the compatible battery range. The stated charging time is a charging specification, rather than an estimate of tool operating time. Actual work per charge depends on the tool and its operating task. Use the battery and charger combination specified for the selected tool system. Compatibility depends on the identified battery interface and tool models, so matching voltage alone is insufficient when choosing a battery or charger. For an existing tool kit, compare the complete model number before replacing a battery or adding a charging component. A rechargeable tool setup includes the tool, its battery and the applicable charger. Keeping those components identified together supports planning for repeated work, replacement batteries, and charging between operations. Battery capacity and charging time describe different characteristics, and neither should be read as a guaranteed number of cuts or crimps for every application. This accessory supplies its stated role within that tool system. Review the tool's instructions for battery installation, charging and use, and keep the accessory model with the tool information when organizing the kit. That helps maintain a clear record of the compatible components used at each working location. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664114942188,"sku":"LI-18-B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/LI-18-B.png?v=1791310049"},{"product_id":"penn-union-m-fp","title":"Penn-Union M-FP","description":"\u003cp\u003eThe Penn-Union M-FP is a 10,000-psi manual foot pump for supplying hydraulic pressure to a compatible tool setup. The pump is the pressure-producing component of the arrangement, connected to the driven tool through the hydraulic hose and coupling system. Two-stage operation provides rapid advance before the high-pressure working stage. An automatic bypass valve operates when maximum pressure is reached. A knob-type release valve gives the operator a defined means of releasing the pressure after the working operation. An integral handle lock assists carrying the pump between locations. A 6-foot hydraulic hose with a quick-connect coupler is included, supplying the listed connection accessory for the pump setup. The pressure specification is a pump characteristic; the output force and working capacity of the connected tool depend on that tool and the complete approved arrangement. Select the pump together with the remote tool, hose and couplers required for the connection task. Compare pressure requirements and mating interfaces before assembling the components, and use the applicable instructions for the chosen tool and pump combination. That keeps the pressure source aligned with the equipment it will operate. In a working layout, allow space for the pump controls and a suitable route for the hose to the tool head. The operator needs access to the advance and release functions, while the tool head needs room for the connector or cable being worked. Considering both locations helps establish how the complete hydraulic arrangement will be used within the available work area. For repeated installation work, keep the pump model and tool information together with the relevant operating instructions. This supports selection of compatible replacement accessories and preserves the details of the hydraulic setup between jobs.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664115400940,"sku":"M-FP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/M-FP.png?v=1791310051"},{"product_id":"penn-union-m-hp","title":"Penn-Union M-HP","description":"\u003cp\u003eThe Penn-Union M-HP is a 10,000-psi manual hand pump for supplying hydraulic pressure to a compatible tool setup. The pump is the pressure-producing component of the arrangement, connected to the driven tool through the hydraulic hose and coupling system. Two-stage operation provides rapid advance before the high-pressure working stage. An automatic bypass valve operates when maximum pressure is reached. A knob-type release valve gives the operator a defined means of releasing the pressure after the working operation. An integral handle lock assists carrying the pump between locations. A 6-foot hydraulic hose with a quick-connect coupler is included, supplying the listed connection accessory for the pump setup. The pressure specification is a pump characteristic; the output force and working capacity of the connected tool depend on that tool and the complete approved arrangement. Select the pump together with the remote tool, hose and couplers required for the connection task. Compare pressure requirements and mating interfaces before assembling the components, and use the applicable instructions for the chosen tool and pump combination. That keeps the pressure source aligned with the equipment it will operate. In a working layout, allow space for the pump controls and a suitable route for the hose to the tool head. The operator needs access to the advance and release functions, while the tool head needs room for the connector or cable being worked. Considering both locations helps establish how the complete hydraulic arrangement will be used within the available work area. For repeated installation work, keep the pump model and tool information together with the relevant operating instructions. This supports selection of compatible replacement accessories and preserves the details of the hydraulic setup between jobs.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664116056300,"sku":"M-HP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/M-HP.png?v=1791310054"},{"product_id":"penn-union-mp-1810","title":"Penn-Union MP-1810","description":"\u003cp\u003eThe Penn-Union MP-1810 is a multi-purpose tool for electrical connection work. The stated conductor range is 18 - 10 AWG Terminals. Match that size range with the connector or terminal type specified for this model when planning the installation. Its operating format determines how the working head is brought to the cable or connector and how the installation stroke is applied. A black oxide finish protects the specified tool surfaces against corrosion. High-carbon steel forms the body of the multipurpose tool. A serrated nose provides a gripping surface for pulling and straightening wire. Contoured grips support comfortable hand placement and control of the tool. The integrated stripping function supports wire preparation before termination. A scale marked in millimeters and inches supplies a measurement reference on the tool. Choose the tool by the complete connection task, including the conductor material, cable size, connector construction, and required installation method. A conductor range describes capacity, while the connector instructions establish the permitted tooling combination and working procedure. Considering these together helps build a tool setup suited to the connection being made rather than relying on size alone. For repeated installation work, keeping the tool model and the connector instructions together makes it easier to confirm the setup before starting each group of connections. Prepare the conductor and position the connector according to the applicable instructions, then use the specified working stroke or crimp sequence for that combination. The working head must also have enough access for cable placement and removal within the actual assembly. This model supplies the operating mechanism for the stated task. The finished connection or cut also depends on the cable being used, its positioning, and the applicable procedure. Review those details when selecting a replacement tool or adding a model to an existing electrical installation kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664116187372,"sku":"MP-1810","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/MP-1810.png?v=1791310057"},{"product_id":"penn-union-pg-1000","title":"Penn-Union PG-1000","description":"\u003cp\u003eThe Penn-Union PG-1000 is an in-line pressure gauge kit for measuring the oil pressure of hydraulic pumps. Its maximum working pressure is 10,000 psi, and it uses a 2.5-inch-diameter gauge with a 3\/8-inch NPT connection. The in-line format places pressure measurement within the hydraulic arrangement, providing a gauge reading for the oil pressure at that location. The dial size describes the gauge face, while the NPT specification identifies its connection to the surrounding system. When planning the hydraulic arrangement, compare the component's stated pressure limit and connection details with the remaining equipment. A matching thread is one part of the interface; the pump, hose, couplers and driven tool also need to form a suitable complete system. Review the applicable equipment instructions for the connection and operating procedure. For replacement or service work, the full part number helps distinguish the component from another accessory with a similar appearance. Record the pressure specification, interface and stated function together so the replacement can be matched to the actual arrangement. Position the assembled components with attention to the working space and the route between the pump and tool. The gauge reading supplies pressure information for the hydraulic oil at the connected measurement point. It does not directly measure the crimp profile or identify the connector being installed. Use the pressure reading as part of the pump evaluation procedure for the equipment in question, with the measurement connection and gauge range matched to that setup. Keep the accessory's full catalog number with the relevant equipment information when ordering a replacement. This identifies the selected component precisely and helps preserve the intended combination of parts within the working kit.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664116515052,"sku":"PG-1000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/PG-1000.png?v=1791310059"},{"product_id":"penn-union-pu-15","title":"Penn-Union PU-15","description":"\u003cp\u003eThe Penn-Union PU-15 is a U-die adapter for the TPU-1500H 15-ton remote hydraulic compression tool. It allows that tool to accept industry-standard 12-ton U-style dies, bringing the U-die interface into the specified larger tool head. The adapter therefore forms the interface between the compression head and the removable working dies. It is a tooling accessory rather than the crimp profile itself: the selected U-type die supplies the profile, while the TPU-1500H supplies the operating force. Penn-Union identifies this adapter specifically for the TPU-1500H, so that model identity should remain part of the selected tooling arrangement. Match the adapter, tool and die as a complete setup for the connector being installed. The connector instructions determine the required die designation and compression procedure, while the adapter establishes the stated fit within the tool head. This separation of roles is useful when assembling a tooling kit or replacing one component in an existing setup. A die that fits an adapter still needs to be the specified die for the conductor and connector combination. For installation work, confirm the full tool and die part numbers before starting the compression operation. Include the adapter requirement in the tooling record so the intended arrangement can be reproduced for later connections. The accessory is particularly relevant where U-type dies are used with the identified 15-ton head. Compare the applicable tool and connector instructions together when planning the installation, including the required crimp sequence and the working clearance at the connection. Keeping those details with the adapter helps preserve the intended tool configuration between jobs.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664117104876,"sku":"PU-15","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/PU-15.png?v=1791310061"},{"product_id":"penn-union-pw-161","title":"Penn-Union PW-161","description":"\u003cp\u003eThe Penn-Union PW-161 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664117170412,"sku":"PW-161","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES.png?v=1791310064"},{"product_id":"penn-union-pw-162","title":"Penn-Union PW-162","description":"\u003cp\u003eThe Penn-Union PW-162 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664117465324,"sku":"PW-162","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_0493022f-8b89-411a-aac6-0ff8e00281f1.png?v=1791310066"},{"product_id":"penn-union-pw-163","title":"Penn-Union PW-163","description":"\u003cp\u003eThe Penn-Union PW-163 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664117924076,"sku":"PW-163","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_da63a5d7-fb9a-43fb-8185-9620cea67a0b.png?v=1791310069"},{"product_id":"penn-union-pw-164","title":"Penn-Union PW-164","description":"\u003cp\u003eThe Penn-Union PW-164 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664118022380,"sku":"PW-164","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_ca6525d0-f426-45d0-89d2-4b9f9a0bf990.png?v=1791310071"},{"product_id":"penn-union-pw-165","title":"Penn-Union PW-165","description":"\u003cp\u003eThe Penn-Union PW-165 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664118546668,"sku":"PW-165","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_83cd7d75-2eaf-4816-88c4-60d34d4dd9ca.png?v=1791310074"},{"product_id":"penn-union-pw-166","title":"Penn-Union PW-166","description":"\u003cp\u003eThe Penn-Union PW-166 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664118644972,"sku":"PW-166","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_9c65cdc9-55d1-40f3-9134-ab2f111884aa.png?v=1791310076"},{"product_id":"penn-union-pw-167","title":"Penn-Union PW-167","description":"\u003cp\u003eThe Penn-Union PW-167 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664119726316,"sku":"PW-167","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_c42b243c-cdd4-4841-99c7-696d4b855389.png?v=1791310078"},{"product_id":"penn-union-pw-171","title":"Penn-Union PW-171","description":"\u003cp\u003eThe Penn-Union PW-171 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664119922924,"sku":"PW-171","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_1dcbf8ee-1810-4e0b-a062-f5c01cf03265.png?v=1791310081"},{"product_id":"penn-union-pw-236","title":"Penn-Union PW-236","description":"\u003cp\u003eThe Penn-Union PW-236 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664121626860,"sku":"PW-236","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_e03c5cf2-7bc9-4194-b73a-02ff451145db.png?v=1791310084"},{"product_id":"penn-union-pw-238","title":"Penn-Union PW-238","description":"\u003cp\u003eThe Penn-Union PW-238 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664128835820,"sku":"PW-238","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_6710f7f3-6bf3-42e3-a997-fbd5f349fd94.png?v=1791310087"},{"product_id":"penn-union-pw-239","title":"Penn-Union PW-239","description":"\u003cp\u003eThe Penn-Union PW-239 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664130244844,"sku":"PW-239","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_cc5e5a8a-1583-43fb-b05e-382f30be37ee.png?v=1791310090"},{"product_id":"penn-union-pw-241","title":"Penn-Union PW-241","description":"\u003cp\u003eThe Penn-Union PW-241 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664134013164,"sku":"PW-241","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_e36fd5c6-eef9-4334-8dfc-5ac5e1a02a76.png?v=1791310092"},{"product_id":"penn-union-pw-243","title":"Penn-Union PW-243","description":"\u003cp\u003eThe Penn-Union PW-243 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664137912556,"sku":"PW-243","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_9d9b8864-065c-4164-8f51-91566153bcf9.png?v=1791310094"},{"product_id":"penn-union-pw-245","title":"Penn-Union PW-245","description":"\u003cp\u003eThe Penn-Union PW-245 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664142041324,"sku":"PW-245","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_fe1e81bc-6731-4873-864b-4b91b7009aee.png?v=1791310096"},{"product_id":"penn-union-pw-247","title":"Penn-Union PW-247","description":"\u003cp\u003eThe Penn-Union PW-247 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664142106860,"sku":"PW-247","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_17898b63-356a-46b3-839d-146743248069.png?v=1791310098"},{"product_id":"penn-union-pw-248","title":"Penn-Union PW-248","description":"\u003cp\u003eThe Penn-Union PW-248 is a W-type compression die for use with 4 to 6-ton tooling. It supplies the working crimp profile in a compatible compression tool, forming part of the tooling combination used to install a connector onto a conductor. Selecting a die is therefore a connection-specific choice: the die style determines the tooling interface, while the connector instructions determine which profile is needed for the conductor and connector being installed. Penn-Union identifies this model as compatible with the TMU-OD3 mechanical compression tool. That compatibility gives the die a defined place in the tool system rather than requiring a complete compression tool for each individual profile. The removable insert approach allows an installer to select the specified die while continuing to use the compatible tool. For this product, the W-type identification and 4-to-6-ton tooling classification describe the intended die system; they do not establish a universal fit with every compression tool of a similar output force. For a new installation or a replacement insert, match the complete die part number to the connector tooling instructions. Conductor size alone is not enough to select the working profile, because the connector material and barrel design also belong to the crimp specification. Keeping the die identity with the tool and connector information helps maintain a consistent installation setup across repeated connections. The die is the forming component in that setup: the tool supplies the operating force, and the connector receives the compression around the conductor. Review all three components together when building a tooling kit. This gives the installer a practical way to choose the correct insert without substituting a visually similar profile or assuming that tool tonnage by itself confirms compatibility.\u003c\/p\u003e","brand":"Penn-Union","offers":[{"title":"New","offer_id":67664145318124,"sku":"PW-248","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/W-DIES_d820b6c5-48d5-4b58-a3a2-2a4c216bd96f.png?v=1791310101"}],"url":"https:\/\/www.industrialautomationco.com\/es-mx\/collections\/penn-union-tools-dies.oembed","provider":"Industrial Automation Co.","version":"1.0","type":"link"}