{"product_id":"yaskawa-cps-12n","title":"Yaskawa CPS-12N","description":"\u003ch2\u003eYaskawa CPS-12N\u003c\/h2\u003e\n\u003cp\u003eThe Yaskawa CPS-12N is a dependable DC power supply unit tailored for advanced manufacturing and CNC applications. Part of the Yasnac series, it ensures consistent performance, boosting the efficiency and reliability of machine tools and automation systems.\u003c\/p\u003e\n\u003ch2\u003eTechnical Features:\u003c\/h2\u003e\n\u003cp\u003e The Yaskawa CPS-12N power supply accommodates input voltages of 200 V-AC, 220 V-AC, and 230 V-AC, enabling global use and compatibility with different electrical standards. This adaptability ensures reliable performance in various industrial settings. The CPS-12N offers versatile output voltages of 5 V-DC, 12 V-DC, and 24 V-DC. This range accommodates various applications, from precise CNC machinery control to powering essential industrial components, ensuring consistent and stable operation.\u003c\/p\u003e\n\u003cp\u003eThe Yaskawa YASNAC CPS-12N DC power supply unit includes five connectors labeled CN01, CN02, CN03, CN04, and CN05. These connectors facilitate easy integration and seamless installation across various industrial systems.\u003c\/p\u003e\n\u003cp\u003eCapacitors within the CPS-12N are crucial electrical components. They achieve maximum capacitance through narrow separation between large conductor areas, often called \"plates.\" This terminology originates from early capacitor construction methods.\u003c\/p\u003e\n\u003ch2\u003eAmbient Conditions:\u003c\/h2\u003e\n\u003cp\u003eThe Yaskawa CPS-12N is designed to function optimally within a specific range of environmental conditions. The ideal operating temperature for this power supply unit ranges from 0°C to 50°C (32°F to 122°F).\u003c\/p\u003e\n\u003cp\u003eThe recommended operating humidity for the CPS-12N is between 20% and 85% non-condensing. Maintaining humidity within this range prevents moisture buildup, lowering the risk of short circuits and other electrical issues. \u003c\/p\u003e\n\u003cp\u003eThe CPS-12N is built to withstand certain levels of vibration and shock, making it suitable for industrial environments where such conditions are common. It can tolerate vibrations up to 0.5G in a frequency spectrum of 10Hz to 55Hz. \u003c\/p\u003e\n\u003ch2\u003e Installation Instructions for Yaskawa CPS-12N:\u003c\/h2\u003e\n\u003cp\u003eBefore beginning the Yaskawa CPS-12N power supply installation, ensure you have all the necessary tools and safety equipment. Verify that the CPS-12N is compatible with your system and meets the required specifications.\u003c\/p\u003e\n\u003cp\u003eDouble-check all connections and mounting hardware before powering up the CPS-12N to ensure no short circuits or exposed wires. Power up the unit and observe the initial startup sequence, checking for error indicators or abnormal behavior.\u003c\/p\u003e\n\u003cp\u003eOnce powered on, perform a series of tests to verify correct functionality. Measure the output voltages to ensure they are within the specified ranges. Adjust settings or calibration parameters as necessary according to your system requirements.\u003c\/p\u003e\n\u003cp\u003eConduct a final inspection to confirm all connections are secure and that there are no signs of overheating or other issues. Ensure the CPS-12N operates within its specified parameters and provides stable power to your system.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions:\u003c\/h2\u003e\n\u003ch3\u003e How much does the Yaskawa CPS-12N power supply unit weigh? \u003c\/h3\u003e\n\u003cp\u003eThe CPS-12N power supply unit weighs 3.40 lbs, allowing easier handling and installation. Its light weight makes it convenient for technicians to integrate into various industrial setups with minimal physical effort.\u003c\/p\u003e\n\u003ch3\u003eWhat are the dimensions of the CPS-12N power supply unit? \u003c\/h3\u003e\n\u003cp\u003eThe CPS-12N power supply unit has dimensions of 5.50\" (H) x 3.00\" (W) x 10.50\" (D). Its compact size facilitates seamless integration into confined spaces within industrial control panels or machinery, offering versatility for various configurations. \u003c\/p\u003e\n\u003ch3\u003eAt what altitude can the Yaskawa CPS-12N operate efficiently?\u003c\/h3\u003e\n\u003cp\u003eThe Yaskawa CPS-12N is engineered to operate efficiently at altitudes up to 1000 meters (3280 feet) above sea level. This altitude range ensures optimal performance and effective cooling, which is crucial for reliable operation in diverse environmental conditions.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications Table\u003c\/h2\u003e\n\u003ctable\u003e\n        \u003ctr\u003e\n            \u003cth\u003eAttribute\u003c\/th\u003e\n            \u003cth\u003eSpecifications\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSeries\u003c\/td\u003e\n            \u003ctd\u003eYASNAC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eVoltage\u003c\/td\u003e\n            \u003ctd\u003eInput Voltage: 200\/220\/230 VAC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDimensions\u003c\/td\u003e\n            \u003ctd\u003e5.50\" (H) x 3.00\" (W) x 10.50\" (D)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFrequency Range\u003c\/td\u003e\n            \u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eWeight\u003c\/td\u003e\n            \u003ctd\u003e3.40 lbs\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eOperating Altitude\u003c\/td\u003e\n            \u003ctd\u003e1000 meters above sea-level\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eProduct Status\u003c\/td\u003e\n            \u003ctd\u003eDicontinued by Manufacturer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eManufacturer\u003c\/td\u003e\n            \u003ctd\u003eYaskawa\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n            \u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePower Rating\u003c\/td\u003e\n            \u003ctd\u003e300 VA\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e","brand":"Yaskawa","offers":[{"title":"IAC Certified Refurbished","offer_id":44007503823084,"sku":"CPS-12N-R","price":2141.02,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/yaskawa-cps-12n-iac-certified-refurbished-303.jpg?v=1762535475","url":"https:\/\/www.industrialautomationco.com\/en-ca\/products\/yaskawa-cps-12n","provider":"Industrial Automation Co.","version":"1.0","type":"link"}