{"title":"WEG RW Thermal \u0026 Electronic Overload Relays","description":"\u003cp\u003eWEG RW overload relays protect the motor behind a CWB or CWM contactor. The RW27, RW67, RW117 and RW317 thermal relays mount directly on the matching contactor frame with phase-loss sensitivity and manual\/automatic reset; the RW-E electronic relays add wider current ranges and selectable trip classes. Match the relay to the contactor frame and the motor full-load current, and we check it before shipping.\u003c\/p\u003e\u003cp\u003eIndustrial Automation Co is an authorized WEG distributor for WEG electrical products: every unit is new and carries WEG's manufacturer warranty. Send us the part number from your existing unit or the motor nameplate and we confirm the match and the lead time before you order.\u003c\/p\u003e","products":[{"product_id":"weg-bf117d","title":"WEG BF117D","description":"\u003cp\u003eThe WEG \u003cstrong\u003eBF117D\u003c\/strong\u003e (WEG material number 10045719) is a mounting base for RW thermal overload relays. Key specifications: reference BF.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Mounting Base range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG BF117D Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eBF117D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10045719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eBF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Mounting Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG BF117D in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48079486386412,"sku":"BF117D-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48079486419180,"sku":"BF117D-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_70a57a9b-dde1-4f93-9e4f-e639c9b45c5a.jpg?v=1789569601"},{"product_id":"weg-bf27-2d","title":"WEG BF27-2D","description":"\u003cp\u003eThe WEG \u003cstrong\u003eBF27-2D\u003c\/strong\u003e (WEG material number 13598034) is a mounting base for RW thermal overload relays. Key specifications: reference BF.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Mounting Base range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG BF27-2D Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eBF27-2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e13598034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eBF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Mounting Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG BF27-2D in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48079592653036,"sku":"BF27-2D-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48079592685804,"sku":"BF27-2D-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_55c1b67d-f672-46c4-993b-b1f3d302d599.jpg?v=1789569602"},{"product_id":"weg-rw27-1d3-u017","title":"WEG RW27-1D3-U017","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D3-U017\u003c\/strong\u003e (WEG material number 10452204) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D3-U017 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D3-U017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10452204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e11-17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e40gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D3-U017 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48100392501484,"sku":"RW27-1D3-U017-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48100392534252,"sku":"RW27-1D3-U017-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_96034879-6125-452c-88a8-0fab3d66c4c3.jpg?v=1789569142"},{"product_id":"weg-rw27-1d2-d028","title":"WEG RW27-1D2-D028","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D2-D028\u003c\/strong\u003e (WEG material number 10047200) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 2 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D2-D028 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D2-D028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10047200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e1,8-2,8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D2-D028 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48100430250220,"sku":"RW27-1D2-D028-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48100430282988,"sku":"RW27-1D2-D028-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_d4293271-a72e-4eb4-a058-c848d7d6815c.jpg?v=1789569140"},{"product_id":"weg-lw1-s300","title":"WEG LW1-S300","description":"\u003cp\u003eThe WEG \u003cstrong\u003eLW1-S300\u003c\/strong\u003e (WEG material number 14397670) is a terminal lug for RW thermal overload relays. Key specifications: terminal type Terminal lug, rated voltage 600 V.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Terminal Lug range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG LW1-S300 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLW1-S300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e14397670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLW1-S300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal type\u003c\/th\u003e\n\u003ctd\u003eTerminal lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Terminal Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG LW1-S300 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48105534521580,"sku":"LW1-S300-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48105534554348,"sku":"LW1-S300-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_d40aa585-b9df-4893-9fd3-3288faff49d4.jpg?v=1789569599"},{"product_id":"weg-lw2-s300","title":"WEG LW2-S300","description":"\u003cp\u003eThe WEG \u003cstrong\u003eLW2-S300\u003c\/strong\u003e (WEG material number 14397718) is a terminal lug for RW thermal overload relays. Key specifications: terminal type Terminal lug, rated voltage 600 V.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Terminal Lug range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG LW2-S300 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLW2-S300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e14397718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLW2-S300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal type\u003c\/th\u003e\n\u003ctd\u003eTerminal lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Terminal Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG LW2-S300 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48105685090540,"sku":"LW2-S300-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48105685123308,"sku":"LW2-S300-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_49154321-1749-446f-8dc0-b856d03c0d37.jpg?v=1789569604"},{"product_id":"weg-lw2-s600","title":"WEG LW2-S600","description":"\u003cp\u003eThe WEG \u003cstrong\u003eLW2-S600\u003c\/strong\u003e (WEG material number 14397719) is a terminal lug for RW thermal overload relays. Key specifications: terminal type Terminal lug, rated voltage 600 V.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Terminal Lug range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG LW2-S600 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLW2-S600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e14397719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLW2-S600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal type\u003c\/th\u003e\n\u003ctd\u003eTerminal lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Terminal Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG LW2-S600 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48105685942508,"sku":"LW2-S600-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48105685975276,"sku":"LW2-S600-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_0dce0464-adb1-48e1-a64a-9d559afaad1a.jpg?v=1789569599"},{"product_id":"weg-lw1-s600","title":"WEG LW1-S600","description":"\u003cp\u003eThe WEG \u003cstrong\u003eLW1-S600\u003c\/strong\u003e (WEG material number 14397675) is a terminal lug for RW thermal overload relays. Key specifications: terminal type Terminal lug, rated voltage 600 V.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Terminal Lug range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG LW1-S600 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eLW1-S600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e14397675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLW1-S600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal type\u003c\/th\u003e\n\u003ctd\u003eTerminal lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Terminal Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG LW1-S600 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48106291101932,"sku":"LW1-S600-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48106291134700,"sku":"LW1-S600-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_1c0d5fc5-b33e-4fca-a9e9-a1deeb439ccf.jpg?v=1789569602"},{"product_id":"weg-bf67-1d","title":"WEG BF67.1D","description":"\u003cp\u003eThe WEG \u003cstrong\u003eBF67.1D\u003c\/strong\u003e (WEG material number 10410086) is a mounting base for RW thermal overload relays. WEG lists it as “MOUNTING BASE BF67-1D”. Key specifications: reference BF.\u003c\/p\u003e\u003cp\u003eGenuine WEG accessory from the Mounting Base range, designed to fit and work with the corresponding WEG controls.\u003c\/p\u003e\u003ch3\u003eWEG BF67.1D Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eBF67.1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10410086\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eMOUNTING BASE BF67-1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eOverload Relay Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eBF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Accessories for Controls \u0026gt; Accessories Thermal Overload Relays - RW \u0026gt; Mounting Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG BF67.1D in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48106771087596,"sku":"BF67.1D-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48106771120364,"sku":"BF67.1D-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Acess_Controls_Generica_1200Wx1200H_c54eba02-64ba-438d-bba9-39381576a3fd.jpg?v=1789569605"},{"product_id":"weg-rwm40e-3-a4u040","title":"WEG RWM40E-3-A4U040","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRWM40E-3-A4U040\u003c\/strong\u003e (WEG material number 11373597) is an RW_E-series solid state overload relay for motor protection. Key specifications: current range 8-40 A, Application\/mounting For contactor CWM, type Electronic, trigger class 10.20.30.\u003c\/p\u003e\u003cp\u003eProtection of low voltage three-phase electric motors on sinusoidal 50\/60 Hz networks is the role of the RW_E, aimed at installations where reliability, low power dissipation and easy maintenance management are required.\u003c\/p\u003e\u003ch3\u003eWEG RWM40E-3-A4U040 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRWM40E-3-A4U040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e11373597\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eSolid State Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW_E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e8-40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\/mounting\u003c\/th\u003e\n\u003ctd\u003eFor contactor CWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrigger class\u003c\/th\u003e\n\u003ctd\u003e10.20.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW_E - Solid state overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RWM40E-3-A4U040 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111289336044,"sku":"RWM40E-3-A4U040-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111289368812,"sku":"RWM40E-3-A4U040-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Rele_Sobrecarga_RWM40Ez_1200Wx1200H_2f76e843-cffb-4d15-9838-8292673c3247.jpg?v=1789569125"},{"product_id":"weg-rw117-3d3-u080","title":"WEG RW117-3D3-U080","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW117-3D3-U080\u003c\/strong\u003e (WEG material number 14204758) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW117-3D3-U080”. Key specifications: reference RW117, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW117-3D3-U080 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW117-3D3-U080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e14204758\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW117-3D3-U080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB95-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e63-80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e200gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e100 mm \/ 3.94 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e75 mm \/ 2.95 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e99 mm \/ 3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,490 kg \/ 1.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW117-3D3-U080 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111300247788,"sku":"RW117-3D3-U080-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111300280556,"sku":"RW117-3D3-U080-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Overload_Relays_RW117_3D_1200Wx1200H.jpg?v=1789569126"},{"product_id":"weg-rw67-1d2-u040","title":"WEG RW67-1D2-U040","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW67-1D2-U040\u003c\/strong\u003e (WEG material number 10047208) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW67, number of poles 2 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW67-1D2-U040 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW67-1D2-U040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10047208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM32\/40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e25-40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e90gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e73 mm \/ 2.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e50 mm \/ 1.97 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e106 mm \/ 4.17 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,320 kg \/ 0.71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW67-1D2-U040 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111301755116,"sku":"RW67-1D2-U040-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111301787884,"sku":"RW67-1D2-U040-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_d1a983d2-31bd-4825-8bb8-844bdc80b430.jpg?v=1789569143"},{"product_id":"weg-rw27-1d3-u032","title":"WEG RW27-1D3-U032","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D3-U032\u003c\/strong\u003e (WEG material number 10452382) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D3-U032 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D3-U032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10452382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e22-32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e63gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D3-U032 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111313420524,"sku":"RW27-1D3-U032-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111313453292,"sku":"RW27-1D3-U032-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_b1aa0992-5bd3-4852-a164-e20e7a4f04ac.jpg?v=1789569139"},{"product_id":"weg-rw27-2d3-u004","title":"WEG RW27-2D3-U004","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-2D3-U004\u003c\/strong\u003e (WEG material number 12140447) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW27-2D3-U004”. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-2D3-U004 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-2D3-U004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12140447\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW27-2D3-U004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB9-38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e2,8-4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e10gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-2D3-U004 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111317057772,"sku":"RW27-2D3-U004-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111317090540,"sku":"RW27-2D3-U004-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_2D_1200Wx1200H_86249213-7200-4cd4-ad60-c9a7e8ee88f0.jpg?v=1789569137"},{"product_id":"weg-rw27-1d2-u032","title":"WEG RW27-1D2-U032","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D2-U032\u003c\/strong\u003e (WEG material number 10047207) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 2 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D2-U032 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D2-U032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10047207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e22-32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e63gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D2-U032 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111323709676,"sku":"RW27-1D2-U032-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111323742444,"sku":"RW27-1D2-U032-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_fa35727c-06bb-46b7-a4c5-268ddd10703b.jpg?v=1789569140"},{"product_id":"weg-rw17-1d3-d125","title":"WEG RW17-1D3-D125","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW17-1D3-D125\u003c\/strong\u003e (WEG material number 12450906) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW17-1D3-D125”. Key specifications: reference RW17, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW17-1D3-D125 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW17-1D3-D125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12450906\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW17-1D3-D125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWC07-16, CW07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e8-12,5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e25gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW17-1D3-D125 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111328493804,"sku":"RW17-1D3-D125-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111328526572,"sku":"RW17-1D3-D125-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW17D_1200Wx1200H_58fd6c42-13eb-464d-98d1-0613921b5725.jpg?v=1789569129"},{"product_id":"weg-rw027-1d3-d125","title":"WEG RW027-1D3-D125","description":"\u003cp\u003eThis WEG \u003cstrong\u003eRW027-1D3-D125\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 8-12.5 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-D125 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the RW027-1D3-D125 in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Reach out to our sales team for availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111331082476,"sku":"RW027-1D3-D125-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111331115244,"sku":"RW027-1D3-D125-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_d84948fd-0aad-4f95-9480-74451bca8fc1.jpg?v=1785816384"},{"product_id":"weg-rw117-1d3-u112","title":"WEG RW117-1D3-U112","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW117-1D3-U112\u003c\/strong\u003e (WEG material number 10410003) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW117, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW117-1D3-U112 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW117-1D3-U112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10410003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM95\/105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e90-112 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e100 mm \/ 3.94 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e75 mm \/ 2.95 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e99 mm \/ 3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,490 kg \/ 1.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW117-1D3-U112 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111335702764,"sku":"RW117-1D3-U112-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111335735532,"sku":"RW117-1D3-U112-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_e89bf762-5fd3-49ca-9ec1-f890014a73cd.jpg?v=1789569139"},{"product_id":"weg-rw117-2d3-u097","title":"WEG RW117-2D3-U097","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW117-2D3-U097\u003c\/strong\u003e (WEG material number 10045646) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW117, number of poles 3 poles, mounting type Individual.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW117-2D3-U097 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW117-2D3-U097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10045646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eIndividual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e75-97 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e225gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e100 mm \/ 3.94 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e75 mm \/ 2.95 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e99 mm \/ 3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,750 kg \/ 1.65 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW117-2D3-U097 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111339405548,"sku":"RW117-2D3-U097-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111339438316,"sku":"RW117-2D3-U097-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H.jpg?v=1789569138"},{"product_id":"weg-rw317-1d3-u420","title":"WEG RW317-1D3-U420","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW317-1D3-U420\u003c\/strong\u003e (WEG material number 10410007) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW317, number of poles 3 poles, mounting type Individual.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW317-1D3-U420 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW317-1D3-U420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10410007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eIndividual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM112-450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e275-420 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e710gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e155 mm \/ 6.10 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e115 mm \/ 4.53 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e166 mm \/ 6.54 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e1,985 kg \/ 4.38 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW317-1D3-U420 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111343042796,"sku":"RW317-1D3-U420-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111343075564,"sku":"RW317-1D3-U420-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_de607240-fad8-4070-bd3f-ea94e6b51394.jpg?v=1789569140"},{"product_id":"weg-rw27-1d3-d008","title":"WEG RW27-1D3-D008","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D3-D008\u003c\/strong\u003e (WEG material number 10186033) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D3-D008 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D3-D008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10186033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e0,56-0,8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e2gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D3-D008 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111345238252,"sku":"RW27-1D3-D008-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111345271020,"sku":"RW27-1D3-D008-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_c3bc589c-631d-47b2-b275-93001e5862a8.jpg?v=1789569140"},{"product_id":"weg-rw67-2d3-u040","title":"WEG RW67-2D3-U040","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW67-2D3-U040\u003c\/strong\u003e (WEG material number 10844133) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW67, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW67-2D3-U040 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW67-2D3-U040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10844133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM50-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e25-40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e90gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e73 mm \/ 2.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e50 mm \/ 1.97 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e106 mm \/ 4.17 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,320 kg \/ 0.71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW67-2D3-U040 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111348056300,"sku":"RW67-2D3-U040-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111348089068,"sku":"RW67-2D3-U040-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_e4796a64-c50d-4243-a06a-13b267dbd9b7.jpg?v=1789569142"},{"product_id":"weg-rw67-1d3-u040","title":"WEG RW67-1D3-U040","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW67-1D3-U040\u003c\/strong\u003e (WEG material number 10452216) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW67, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW67-1D3-U040 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW67-1D3-U040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10452216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM32\/40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e25-40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e90gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e73 mm \/ 2.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e50 mm \/ 1.97 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e106 mm \/ 4.17 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,320 kg \/ 0.71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW67-1D3-U040 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111380562156,"sku":"RW67-1D3-U040-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111380594924,"sku":"RW67-1D3-U040-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_eaf0c4f5-7949-409f-a276-aea7ec574f10.jpg?v=1789569141"},{"product_id":"weg-rw117-1d3-u080","title":"WEG RW117-1D3-U080","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW117-1D3-U080\u003c\/strong\u003e (WEG material number 10186370) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW117, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW117-1D3-U080 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW117-1D3-U080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10186370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM95\/105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e63-80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e200gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e100 mm \/ 3.94 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e75 mm \/ 2.95 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e99 mm \/ 3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,490 kg \/ 1.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW117-1D3-U080 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111383806188,"sku":"RW117-1D3-U080-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111383838956,"sku":"RW117-1D3-U080-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_255aa839-4e60-43a4-be5b-6c3057a2d503.jpg?v=1789569138"},{"product_id":"weg-rw407-1d3-u840","title":"WEG RW407-1D3-U840","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW407-1D3-U840\u003c\/strong\u003e (WEG material number 10045637) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW407, number of poles 3 poles, mounting type Individual.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW407-1D3-U840 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW407-1D3-U840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10045637\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eIndividual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM450-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e560-840 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e1250gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e150 mm \/ 5.91 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e265 mm \/ 10.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e185 mm \/ 7.28 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e3,435 kg \/ 7.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW407-1D3-U840 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111385018604,"sku":"RW407-1D3-U840-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111385051372,"sku":"RW407-1D3-U840-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW_Outros_1200Wx1200H_57ae9e13-b8d0-4ee5-a675-7c4bf78813c1.jpg?v=1789569141"},{"product_id":"weg-rw67-5d3-u070","title":"WEG RW67-5D3-U070","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW67-5D3-U070\u003c\/strong\u003e (WEG material number 13368964) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW67-5D3-U070”. Key specifications: reference RW67, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW67-5D3-U070 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW67-5D3-U070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e13368964\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW67-5D3-U070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB40-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e5D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e57-70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e175gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e73 mm \/ 2.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e50 mm \/ 1.97 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e106 mm \/ 4.17 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,320 kg \/ 0.71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW67-5D3-U070 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111385805036,"sku":"RW67-5D3-U070-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111385837804,"sku":"RW67-5D3-U070-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Rele_de_Sobrecarga_RW67_5D_1200Wx1200H_5c9d412e-666d-4057-bbfc-fa895b6f6a69.jpg?v=1789569139"},{"product_id":"weg-rw027-1d3-u017","title":"WEG RW027-1D3-U017","description":"\u003cp\u003eThis WEG \u003cstrong\u003eRW027-1D3-U017\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 11-17 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-U017 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-U017 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111387640044,"sku":"RW027-1D3-U017-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111387672812,"sku":"RW027-1D3-U017-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_a5948a41-e8d6-4391-846a-85dc17ca9e3f.jpg?v=1785816415"},{"product_id":"weg-rw17-1d3-u015","title":"WEG RW17-1D3-U015","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW17-1D3-U015\u003c\/strong\u003e (WEG material number 12450907) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW17-1D3-U015”. Key specifications: reference RW17, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW17-1D3-U015 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW17-1D3-U015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12450907\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW17-1D3-U015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWC07-16, CW07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e10-15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e35gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW17-1D3-U015 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111392555244,"sku":"RW17-1D3-U015-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111392588012,"sku":"RW17-1D3-U015-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW17D_1200Wx1200H_40cf3c55-0343-4e02-bbea-1ee6151d4439.jpg?v=1789569128"},{"product_id":"weg-rw17-1d3-d012","title":"WEG RW17-1D3-D012","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW17-1D3-D012\u003c\/strong\u003e (WEG material number 12450897) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW17-1D3-D012”. Key specifications: reference RW17, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW17-1D3-D012 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW17-1D3-D012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12450897\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW17-1D3-D012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWC07-16, CW07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e0,8-1,2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e4gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW17-1D3-D012 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111395438828,"sku":"RW17-1D3-D012-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111395471596,"sku":"RW17-1D3-D012-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW17D_1200Wx1200H_1b3b7845-e1c3-4127-b381-306bcb52538d.jpg?v=1789569128"},{"product_id":"weg-rw027-1d3-d028","title":"WEG RW027-1D3-D028","description":"\u003cp\u003eThis WEG \u003cstrong\u003eRW027-1D3-D028\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 1.8-2.8 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-D028 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-D028 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111399305452,"sku":"RW027-1D3-D028-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111399338220,"sku":"RW027-1D3-D028-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_ae560097-63f1-44a6-a875-27d4b70e7f2a.jpg?v=1785816421"},{"product_id":"weg-rw27-1d3-u010","title":"WEG RW27-1D3-U010","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D3-U010\u003c\/strong\u003e (WEG material number 10045634) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D3-U010 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D3-U010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10045634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D3-U010 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111401107692,"sku":"RW27-1D3-U010-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111401140460,"sku":"RW27-1D3-U010-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_a71bbd32-b5e7-45fd-b1a3-890fe5a3686d.jpg?v=1789569141"},{"product_id":"weg-rw27-2d3-d028","title":"WEG RW27-2D3-D028","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-2D3-D028\u003c\/strong\u003e (WEG material number 12140446) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW27-2D3-D028”. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-2D3-D028 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-2D3-D028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12140446\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW27-2D3-D028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB9-38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e1,8-2,8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-2D3-D028 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111414509804,"sku":"RW27-2D3-D028-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111414542572,"sku":"RW27-2D3-D028-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_2D_1200Wx1200H_6ad711a8-d47e-4dba-abc1-f8c2f4ea73c2.jpg?v=1789569133"},{"product_id":"weg-rw067-1d3-u040","title":"WEG RW067-1D3-U040","description":"\u003cp\u003eWEG \u003cstrong\u003eRW067-1D3-U040\u003c\/strong\u003e, a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 25-40 FLA, suitable for use with CWM032,CWM040 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW067-1D3-U040 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM032,CWM040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the RW067-1D3-U040 in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Reach out to our sales team for availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111427682540,"sku":"RW067-1D3-U040-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111427715308,"sku":"RW067-1D3-U040-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_976f9e3a-3e3b-43a9-a302-00a00c83be68.jpg?v=1785816437"},{"product_id":"weg-rw027-1d3-u008","title":"WEG RW027-1D3-U008","description":"\u003cp\u003eThis WEG \u003cstrong\u003eRW027-1D3-U008\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 5.6-8 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-U008 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the RW027-1D3-U008 in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Reach out to our sales team for availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111431811308,"sku":"RW027-1D3-U008-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111431844076,"sku":"RW027-1D3-U008-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_399af8a4-83b8-48a3-a5ea-120b42014524.jpg?v=1785816439"},{"product_id":"weg-rw027-1d3-u023","title":"WEG RW027-1D3-U023","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW027-1D3-U023\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 15-23 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-U023 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-U023 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111433711852,"sku":"RW027-1D3-U023-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111433744620,"sku":"RW027-1D3-U023-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_4402731f-b376-40a7-9d3d-9e60b3b37bde.jpg?v=1785816440"},{"product_id":"weg-rw027-1d3-d012","title":"WEG RW027-1D3-D012","description":"\u003cp\u003eWEG \u003cstrong\u003eRW027-1D3-D012\u003c\/strong\u003e, a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 0.8-1.2 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-D012 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-D012 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111436759276,"sku":"RW027-1D3-D012-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111436792044,"sku":"RW027-1D3-D012-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_14380781-d233-4f0f-9e61-5a8b4391e946.jpg?v=1785816442"},{"product_id":"weg-rw17-1d3-c063","title":"WEG RW17-1D3-C063","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW17-1D3-C063\u003c\/strong\u003e (WEG material number 12450895) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW17-1D3-C063”. Key specifications: reference RW17, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW17-1D3-C063 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW17-1D3-C063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12450895\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW17-1D3-C063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWC07-16, CW07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e0,4-0,63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e2gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW17-1D3-C063 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111438627052,"sku":"RW17-1D3-C063-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111438659820,"sku":"RW17-1D3-C063-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW17D_1200Wx1200H_ae023cf7-9004-4601-bb77-5b54a6b230cf.jpg?v=1789569128"},{"product_id":"weg-rw027-1d3-d008","title":"WEG RW027-1D3-D008","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW027-1D3-D008\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 0.56-0.8 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-D008 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.56 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-D008 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111442100460,"sku":"RW027-1D3-D008-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111442133228,"sku":"RW027-1D3-D008-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_f8729375-261d-4645-b636-06815b30cf20.jpg?v=1785816446"},{"product_id":"weg-rw27-2d3-u040","title":"WEG RW27-2D3-U040","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-2D3-U040\u003c\/strong\u003e (WEG material number 12140456) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW27-2D3-U040”. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-2D3-U040 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-2D3-U040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12140456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW27-2D3-U040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB9-38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e32-40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e125gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-2D3-U040 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111443673324,"sku":"RW27-2D3-U040-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111443706092,"sku":"RW27-2D3-U040-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_2D_1200Wx1200H_a763e243-6b34-4091-8702-07522520fca3.jpg?v=1789569134"},{"product_id":"weg-rw067-2d3-u057","title":"WEG RW067-2D3-U057","description":"\u003cp\u003eThis WEG \u003cstrong\u003eRW067-2D3-U057\u003c\/strong\u003e is a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 40-57 FLA, suitable for use with CWM050,CWM080 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW067-2D3-U057 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM050,CWM080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW067-2D3-U057 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111459172588,"sku":"RW067-2D3-U057-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111459205356,"sku":"RW067-2D3-U057-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_ded575f2-f930-4459-aaf3-57034694626a.jpg?v=1785816456"},{"product_id":"weg-rw27-1d2-d063","title":"WEG RW27-1D2-D063","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D2-D063\u003c\/strong\u003e (WEG material number 10047201) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 2 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D2-D063 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D2-D063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10047201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e2 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e4-6,3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e16gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D2-D063 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111470084332,"sku":"RW27-1D2-D063-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111470117100,"sku":"RW27-1D2-D063-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H.jpg?v=1789569139"},{"product_id":"weg-rw027-1d3-c063","title":"WEG RW027-1D3-C063","description":"\u003cp\u003eWEG \u003cstrong\u003eRW027-1D3-C063\u003c\/strong\u003e, a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 0.4-0.63 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-C063 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-C063 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111470969068,"sku":"RW027-1D3-C063-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111471001836,"sku":"RW027-1D3-C063-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_54c1e2ba-9339-4d16-8d4f-016afab33db6.jpg?v=1785816463"},{"product_id":"weg-rw027-1d3-d004","title":"WEG RW027-1D3-D004","description":"\u003cp\u003eWEG \u003cstrong\u003eRW027-1D3-D004\u003c\/strong\u003e, a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 0.28-0.4 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-D004 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-D004 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111472443628,"sku":"RW027-1D3-D004-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111472476396,"sku":"RW027-1D3-D004-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_edb8cc9b-4088-4a95-a97f-ed2ecfe752ce.jpg?v=1785816464"},{"product_id":"weg-rw27-2d3-d125","title":"WEG RW27-2D3-D125","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-2D3-D125\u003c\/strong\u003e (WEG material number 12140451) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW27-2D3-D125”. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-2D3-D125 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-2D3-D125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12140451\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW27-2D3-D125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB9-38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e8-12,5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e25gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-2D3-D125 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111473787116,"sku":"RW27-2D3-D125-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111473819884,"sku":"RW27-2D3-D125-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_2D_1200Wx1200H_5f27cac5-9671-46dc-a6d8-a8b96251544c.jpg?v=1789569133"},{"product_id":"weg-rw27-1d3-d018","title":"WEG RW27-1D3-D018","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-1D3-D018\u003c\/strong\u003e (WEG material number 10045632) is an RW-series thermal overload relay for motor protection. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-1D3-D018 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-1D3-D018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e10045632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWM9-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e1,2-1,8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-1D3-D018 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111475785964,"sku":"RW27-1D3-D018-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111475818732,"sku":"RW27-1D3-D018-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_1D_1200Wx1200H_f8864d23-1f22-492b-8124-c161dc65bb8d.jpg?v=1789569139"},{"product_id":"weg-rwm420e-3-a4u420","title":"WEG RWM420E-3-A4U420","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRWM420E-3-A4U420\u003c\/strong\u003e (WEG material number 11455846) is an RW_E-series solid state overload relay for motor protection. Key specifications: current range 85-420 A, Application\/mounting For contactor CWM, type Electronic, trigger class 10.20.30.\u003c\/p\u003e\u003cp\u003eProtection of low voltage three-phase electric motors on sinusoidal 50\/60 Hz networks is the role of the RW_E, aimed at installations where reliability, low power dissipation and easy maintenance management are required.\u003c\/p\u003e\u003ch3\u003eWEG RWM420E-3-A4U420 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRWM420E-3-A4U420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e11455846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eSolid State Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW_E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e85-420 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\/mounting\u003c\/th\u003e\n\u003ctd\u003eFor contactor CWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrigger class\u003c\/th\u003e\n\u003ctd\u003e10.20.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW_E - Solid state overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RWM420E-3-A4U420 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111477719276,"sku":"RWM420E-3-A4U420-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111477752044,"sku":"RWM420E-3-A4U420-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Rele_Sobrecarga_RWM420Ez_1200Wx1200H.jpg?v=1789569126"},{"product_id":"weg-rw27-2d3-u032","title":"WEG RW27-2D3-U032","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRW27-2D3-U032\u003c\/strong\u003e (WEG material number 12140455) is an RW-series thermal overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RW27-2D3-U032”. Key specifications: reference RW27, number of poles 3 poles, mounting type Direct.\u003c\/p\u003e\u003cp\u003eRated for electric motors up to 840A, these protection relays mount directly on the contactors or on a separate base, trip class 10.\u003c\/p\u003e\u003ch3\u003eWEG RW27-2D3-U032 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRW27-2D3-U032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e12140455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RW27-2D3-U032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003ctd\u003eRW27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor model\u003c\/th\u003e\n\u003ctd\u003eCWB9-38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting configuration\u003c\/th\u003e\n\u003ctd\u003e2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui (acc. to UL)\u003c\/th\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational frequency\u003c\/th\u003e\n\u003ctd\u003e25...400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitable for use with DC loads\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency\u003c\/th\u003e\n\u003ctd\u003e15 ops.\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - main terminals\u003c\/th\u003e\n\u003ctd\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection - auxiliary terminals\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e22-32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Fuse (type 2 coordination)\u003c\/th\u003e\n\u003ctd\u003e63gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit protection with fuses (gL\/gG)\u003c\/th\u003e\n\u003ctd\u003e6gL\/gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72 mm \/ 2.83 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm \/ 1.77 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e82 mm \/ 3.23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGross weight\u003c\/th\u003e\n\u003ctd\u003e0,165 kg \/ 0.36 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW - Thermal overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RW27-2D3-U032 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111484240108,"sku":"RW27-2D3-U032-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111484272876,"sku":"RW27-2D3-U032-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_RelesdeSobrecarga_Termico_RW27_2D_1200Wx1200H_47745848-fc61-4098-a534-fc231dfa0839.jpg?v=1789569136"},{"product_id":"weg-rwb40e-3-r4u008","title":"WEG RWB40E-3-R4U008","description":"\u003cp\u003eThe WEG \u003cstrong\u003eRWB40E-3-R4U008\u003c\/strong\u003e (WEG material number 14773635) is an RW_E-series solid state overload relay for motor protection. WEG lists it as “OVERLOAD RELAY BU RWB40E-3-R4U008”. Key specifications: current range 1,6-8 A, Application\/mounting For contactor CWB, type Electronic, trigger class 10.20.30.\u003c\/p\u003e\u003cp\u003eProtection of low voltage three-phase electric motors on sinusoidal 50\/60 Hz networks is the role of the RW_E, aimed at installations where reliability, low power dissipation and easy maintenance management are required.\u003c\/p\u003e\u003ch3\u003eWEG RWB40E-3-R4U008 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003eRWB40E-3-R4U008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG material number\u003c\/th\u003e\n\u003ctd\u003e14773635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG designation\u003c\/th\u003e\n\u003ctd\u003eOVERLOAD RELAY BU RWB40E-3-R4U008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eSolid State Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eRW_E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent range\u003c\/th\u003e\n\u003ctd\u003e1,6-8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\/mounting\u003c\/th\u003e\n\u003ctd\u003eFor contactor CWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrigger class\u003c\/th\u003e\n\u003ctd\u003e10.20.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWEG catalog category\u003c\/th\u003e\n\u003ctd\u003eControls \u0026gt; Motor starters and protection \u0026gt; Overload relays \u0026gt; RW_E - Solid state overload relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the WEG RWB40E-3-R4U008 in \u003cstrong\u003enew\u003c\/strong\u003e condition. Request a quote for current pricing, availability, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111484961004,"sku":"RWB40E-3-R4U008-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111484993772,"sku":"RWB40E-3-R4U008-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/WDC_Rele_Sobrecarga_RWB40E_R_1200Wx1200H_17f607cc-927f-4c38-92be-884af1dc87fc.jpg?v=1789569125"},{"product_id":"weg-rw027-1d3-d063","title":"WEG RW027-1D3-D063","description":"\u003cp\u003eWEG \u003cstrong\u003eRW027-1D3-D063\u003c\/strong\u003e, a CWM Series overload relay.\u003c\/p\u003e\u003cp\u003eFactory specification: Thermal overload relay, 1NO-1NC auxiliary contacts, 4-6.3 FLA, suitable for use with CWM009,CWM018,CWM032 AC contactors.\u003c\/p\u003e\u003ch3\u003eRW027-1D3-D063 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCWM009,CWM018,CWM032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe RW027-1D3-D063 is available from Industrial Automation Co. in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Contact our sales team for current availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111491481836,"sku":"RW027-1D3-D063-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111491514604,"sku":"RW027-1D3-D063-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_cc92e7ae-dde2-409e-9d4f-ff124230f750.jpg?v=1785816474"},{"product_id":"weg-rw27d-32","title":"WEG RW27D-32","description":"\u003cp\u003eWEG \u003cstrong\u003eRW27D-32\u003c\/strong\u003e, a overload relay.\u003c\/p\u003e\u003ch3\u003eRW27D-32 Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eIndustrial Automation Co. offers the RW27D-32 in \u003cstrong\u003eNew\u003c\/strong\u003e and \u003cstrong\u003eIAC Certified Refurbished\u003c\/strong\u003e condition. Reach out to our sales team for availability, pricing, and lead time.\u003c\/p\u003e","brand":"WEG","offers":[{"title":"New","offer_id":48111491875052,"sku":"RW27D-32-FS","price":0.0,"currency_code":"USD","in_stock":false},{"title":"IAC Certified Refurbished","offer_id":48111491907820,"sku":"RW27D-32-R","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0217\/1112\/6600\/files\/group-066_fd745305-c708-4db7-b5c6-759d88043bbb.jpg?v=1785816474"}],"url":"https:\/\/www.industrialautomationco.com\/de-de\/collections\/weg-rw-overload-relays.oembed","provider":"Industrial Automation Co.","version":"1.0","type":"link"}